{"title":"LBNL正电子发射乳房x线摄影(PEM)相机的电子系统","authors":"W. Moses, J. Young, K. Baker, W. Jones, M. Lenox, M. Ho, M. Weng","doi":"10.1109/NSSMIC.2000.950022","DOIUrl":null,"url":null,"abstract":"Summary form only received as follows: Describes the electronics for a high performance Positron Emission Mammography (PEM) camera. It is based on the electronics for a human brain PET camera (the Siemens/CTI HRRT), modified to use a detector module that incorporates a photodiode (PD) array. An ASIC services the PD array, amplifying its signal and identifying the crystal of interaction. Another ASIC services the photomultiplier tube (PMT), measuring its output and providing a timing signal. FPGAs and lookup RAMs are used to apply crystal by crystal correction factors and measure the interaction depth (based on the PD/PMT ratio). Further arrays of FPGAs provide event multiplexing, derandomization, coincidence detection, and real-time rebinning. Embedded PC/104 microprocessors provide communication, real-time control, and configure the system. Extensive use of FPGAs make the overall design extremely flexible, allowing many different functions (or design modifications) to be realized without hardware changes. Incorporation of extensive onboard diagnostics, implemented in the FPGAs, is required by the very high level of integration and density achieved by this system.","PeriodicalId":445100,"journal":{"name":"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"The electronics system for the LBNL Positron Emission Mammography (PEM) camera\",\"authors\":\"W. Moses, J. Young, K. Baker, W. Jones, M. Lenox, M. Ho, M. Weng\",\"doi\":\"10.1109/NSSMIC.2000.950022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Summary form only received as follows: Describes the electronics for a high performance Positron Emission Mammography (PEM) camera. It is based on the electronics for a human brain PET camera (the Siemens/CTI HRRT), modified to use a detector module that incorporates a photodiode (PD) array. An ASIC services the PD array, amplifying its signal and identifying the crystal of interaction. Another ASIC services the photomultiplier tube (PMT), measuring its output and providing a timing signal. FPGAs and lookup RAMs are used to apply crystal by crystal correction factors and measure the interaction depth (based on the PD/PMT ratio). Further arrays of FPGAs provide event multiplexing, derandomization, coincidence detection, and real-time rebinning. Embedded PC/104 microprocessors provide communication, real-time control, and configure the system. Extensive use of FPGAs make the overall design extremely flexible, allowing many different functions (or design modifications) to be realized without hardware changes. Incorporation of extensive onboard diagnostics, implemented in the FPGAs, is required by the very high level of integration and density achieved by this system.\",\"PeriodicalId\":445100,\"journal\":{\"name\":\"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2000.950022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2000.950022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

仅收到的摘要表格如下:描述高性能正电子发射乳房x线摄影(PEM)相机的电子设备。它是基于人脑PET相机(西门子/CTI HRRT)的电子设备,修改为使用包含光电二极管(PD)阵列的检测器模块。一个专用集成电路服务于PD阵列,放大其信号并识别交互晶体。另一个专用集成电路服务于光电倍增管(PMT),测量其输出并提供定时信号。fpga和查找ram用于逐个晶体校正因子和测量相互作用深度(基于PD/PMT比)。进一步的fpga阵列提供事件多路复用、非随机化、巧合检测和实时恢复。嵌入式PC/104微处理器提供通信、实时控制和配置系统。fpga的广泛使用使整体设计非常灵活,允许在不改变硬件的情况下实现许多不同的功能(或设计修改)。该系统实现了非常高的集成度和密度,因此需要在fpga中实现广泛的板载诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The electronics system for the LBNL Positron Emission Mammography (PEM) camera
Summary form only received as follows: Describes the electronics for a high performance Positron Emission Mammography (PEM) camera. It is based on the electronics for a human brain PET camera (the Siemens/CTI HRRT), modified to use a detector module that incorporates a photodiode (PD) array. An ASIC services the PD array, amplifying its signal and identifying the crystal of interaction. Another ASIC services the photomultiplier tube (PMT), measuring its output and providing a timing signal. FPGAs and lookup RAMs are used to apply crystal by crystal correction factors and measure the interaction depth (based on the PD/PMT ratio). Further arrays of FPGAs provide event multiplexing, derandomization, coincidence detection, and real-time rebinning. Embedded PC/104 microprocessors provide communication, real-time control, and configure the system. Extensive use of FPGAs make the overall design extremely flexible, allowing many different functions (or design modifications) to be realized without hardware changes. Incorporation of extensive onboard diagnostics, implemented in the FPGAs, is required by the very high level of integration and density achieved by this system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信