{"title":"Hubungan antara Diameter Optic Nerve Sheath pada Grey Scale Ultrasound dengan Peningkatan Tekanan Intrakranial pada Pasien dengan Lesi Intrakranial","authors":"Tatok Rudiharto, Bachtiar Murtala, Sri Asriyani, Mirna Muis, Cahyono Kaelan, Burhanuddin Bahar","doi":"10.33476/MS.V6I1.1156","DOIUrl":null,"url":null,"abstract":"The study aims to determine the correlation between diameter of optic nerve sheath on grey scale with increased intracranial pressure in patients with intracranial lesion. The research was conducted in Radiology Department of Dr. Wahidin Sudirohusodo Makassar from January 2019 – May 2019. The sample were 39 people aged ³18 years old with intracranial lesion. Axial computed tomography (CT) examination was performed to evaluate intracranial lesions and the presence of midline shift. The diameter of the optic nerve sheath was measured using eye ultrasonography. Data analyses used Spearman’s correlation test. The results showed that there was a correlation between the dilatation of the right and left optic nerve sheath diameter with midline shift (p = 0.04; p 0.05) on the diameter of the right optic nerve sheath showing a weak positive relationship (p = 0.02) for the diameter the optic nerve sheath left showing a medium positive relationship where the higher the midline shift, the wider the diameter of the left and right optical nerve sheath. There is a correlation between the right and left optic nerve sheath diameter (p = 0.001) showing a strong positive relationship where the wider the diameter of the right optic nerve sheath, the wider the diameter of the left optic nerve sheath at high intracranial pressure. Statistically other results also obtained no relationship between dilatation of the diameter of the optic nerve sheath with clinical symptoms of increased intracranial pressure and type of lesion.","PeriodicalId":306850,"journal":{"name":"Majalah Sainstekes","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Majalah Sainstekes","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33476/MS.V6I1.1156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在确定颅内病变患者视神经鞘直径与颅内压升高的灰阶相关性。该研究于2019年1月至2019年5月在Wahidin Sudirohusodo Makassar医生的放射科进行。样本为39例18岁的颅内病变患者。进行轴向计算机断层扫描(CT)检查以评估颅内病变和中线移位的存在。用眼超声测量视神经鞘直径。数据分析采用Spearman相关检验。结果显示,左右视神经鞘直径扩张与中线移位有相关性(p = 0.04;P = 0.05)与右侧视神经鞘直径呈弱正相关(P = 0.02),与左侧视神经鞘直径呈中等正相关,中线移位越高,左右视神经鞘直径越宽。左右视神经鞘直径之间存在相关性(p = 0.001),在高颅内压下,右侧视神经鞘直径越宽,左侧视神经鞘直径越宽。其他统计结果也显示视神经鞘直径的扩张与颅内压升高的临床症状和病变类型没有关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hubungan antara Diameter Optic Nerve Sheath pada Grey Scale Ultrasound dengan Peningkatan Tekanan Intrakranial pada Pasien dengan Lesi Intrakranial
The study aims to determine the correlation between diameter of optic nerve sheath on grey scale with increased intracranial pressure in patients with intracranial lesion. The research was conducted in Radiology Department of Dr. Wahidin Sudirohusodo Makassar from January 2019 – May 2019. The sample were 39 people aged ³18 years old with intracranial lesion. Axial computed tomography (CT) examination was performed to evaluate intracranial lesions and the presence of midline shift. The diameter of the optic nerve sheath was measured using eye ultrasonography. Data analyses used Spearman’s correlation test. The results showed that there was a correlation between the dilatation of the right and left optic nerve sheath diameter with midline shift (p = 0.04; p 0.05) on the diameter of the right optic nerve sheath showing a weak positive relationship (p = 0.02) for the diameter the optic nerve sheath left showing a medium positive relationship where the higher the midline shift, the wider the diameter of the left and right optical nerve sheath. There is a correlation between the right and left optic nerve sheath diameter (p = 0.001) showing a strong positive relationship where the wider the diameter of the right optic nerve sheath, the wider the diameter of the left optic nerve sheath at high intracranial pressure. Statistically other results also obtained no relationship between dilatation of the diameter of the optic nerve sheath with clinical symptoms of increased intracranial pressure and type of lesion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信