不同工质工况下回路热管热性能的实验研究

A. Miyara, K. Kariya, K. Htoo, P. Huynh
{"title":"不同工质工况下回路热管热性能的实验研究","authors":"A. Miyara, K. Kariya, K. Htoo, P. Huynh","doi":"10.15377/2409-5826.2019.06.3","DOIUrl":null,"url":null,"abstract":"Nowadays, due to the tremendous development of data centers (DCs), studying the effective cooling methods that can face to the challenges such as the high power or heat flux dissipation and the efficient electricity consumption in DCs has never been unnecessary. Loop heat pipe (LHP), a two-phase heat transfer device, is being considered as one of the potential solutions for the above problems. This paper introduces the experimental study on the thermal performances of LHP functioning under gravity assisted condition with different working fluids that are water and ethanol (C2H5OH). This LHP has the flat-rectangular evaporator with the stainless-steel (SS) sintering wick installed inside. The results demonstrate that under the same condenser cooling condition, water LHP performed better than ethanol LHP. In the case of water LHP, when heating power was increased from 33 to 535 W, the temperature at the top surface of the heating block raised from 38C to 110C. With the ethanol LHP, this temperature reached 133C at the heating power of 395 W. If temperature limitation of microprocessors functioning inside the DCs is recognized at 85C, the cooling capabilities of LHP are 220 W and 350 W corresponding to the working fluid are ethanol and water respectively. In addition, the discussions about the difference in boiling heating transfer characteristics as well as condenser performances between water LHP and ethanol LHP are also presented in this study.","PeriodicalId":244913,"journal":{"name":"Journal of Advanced Thermal Science Research","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Experimental Investigation Thermal Performance of Loop Heat Pipe Operating with Different Working Fluids\",\"authors\":\"A. Miyara, K. Kariya, K. Htoo, P. Huynh\",\"doi\":\"10.15377/2409-5826.2019.06.3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nowadays, due to the tremendous development of data centers (DCs), studying the effective cooling methods that can face to the challenges such as the high power or heat flux dissipation and the efficient electricity consumption in DCs has never been unnecessary. Loop heat pipe (LHP), a two-phase heat transfer device, is being considered as one of the potential solutions for the above problems. This paper introduces the experimental study on the thermal performances of LHP functioning under gravity assisted condition with different working fluids that are water and ethanol (C2H5OH). This LHP has the flat-rectangular evaporator with the stainless-steel (SS) sintering wick installed inside. The results demonstrate that under the same condenser cooling condition, water LHP performed better than ethanol LHP. In the case of water LHP, when heating power was increased from 33 to 535 W, the temperature at the top surface of the heating block raised from 38C to 110C. With the ethanol LHP, this temperature reached 133C at the heating power of 395 W. If temperature limitation of microprocessors functioning inside the DCs is recognized at 85C, the cooling capabilities of LHP are 220 W and 350 W corresponding to the working fluid are ethanol and water respectively. In addition, the discussions about the difference in boiling heating transfer characteristics as well as condenser performances between water LHP and ethanol LHP are also presented in this study.\",\"PeriodicalId\":244913,\"journal\":{\"name\":\"Journal of Advanced Thermal Science Research\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Thermal Science Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15377/2409-5826.2019.06.3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Thermal Science Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15377/2409-5826.2019.06.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

如今,随着数据中心的飞速发展,研究有效的冷却方法以应对数据中心的高功率或高热流密度耗散以及高效电能消耗等挑战已经成为一种迫切需要。循环热管(LHP)是一种两相传热装置,被认为是解决上述问题的潜在方法之一。本文介绍了重力辅助条件下LHP在水和乙醇(C2H5OH)两种不同工质下热工性能的实验研究。这个LHP有扁矩形蒸发器与不锈钢(SS)烧结芯安装在里面。结果表明,在相同的冷凝器冷却条件下,水高效液相色谱的性能优于乙醇高效液相色谱。在水LHP的情况下,当加热功率从33 W增加到535 W时,加热块上表面温度从38C上升到110C。使用乙醇LHP时,加热功率为395 W,温度达到133C。如果识别出dc内部微处理器的温度限制为85℃,则LHP的冷却能力分别为220 W和350 W,对应的工作流体分别为乙醇和水。此外,本文还讨论了水型和乙醇型低沸点锅炉在沸腾传热特性和冷凝器性能上的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental Investigation Thermal Performance of Loop Heat Pipe Operating with Different Working Fluids
Nowadays, due to the tremendous development of data centers (DCs), studying the effective cooling methods that can face to the challenges such as the high power or heat flux dissipation and the efficient electricity consumption in DCs has never been unnecessary. Loop heat pipe (LHP), a two-phase heat transfer device, is being considered as one of the potential solutions for the above problems. This paper introduces the experimental study on the thermal performances of LHP functioning under gravity assisted condition with different working fluids that are water and ethanol (C2H5OH). This LHP has the flat-rectangular evaporator with the stainless-steel (SS) sintering wick installed inside. The results demonstrate that under the same condenser cooling condition, water LHP performed better than ethanol LHP. In the case of water LHP, when heating power was increased from 33 to 535 W, the temperature at the top surface of the heating block raised from 38C to 110C. With the ethanol LHP, this temperature reached 133C at the heating power of 395 W. If temperature limitation of microprocessors functioning inside the DCs is recognized at 85C, the cooling capabilities of LHP are 220 W and 350 W corresponding to the working fluid are ethanol and water respectively. In addition, the discussions about the difference in boiling heating transfer characteristics as well as condenser performances between water LHP and ethanol LHP are also presented in this study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信