一种低成本、体积多换能器相控阵超声系统的设计

Michail Tsakalakis, N. Bourbakis
{"title":"一种低成本、体积多换能器相控阵超声系统的设计","authors":"Michail Tsakalakis, N. Bourbakis","doi":"10.1109/BIBE.2015.7367624","DOIUrl":null,"url":null,"abstract":"There is an undisputed need for increased portability and flexibility in diagnostic ultrasound imaging due to the continuously evolving point of care (POC) clinical applications. In order to meet this growing need numerous portable ultrasound systems have been proposed. The design of portable systems is a very challenging task, especially for volumetric imaging system which utilize transducers with hundreds and thousands of elements. This study presents a new low-cost, portable volumetric ultrasound system for ambulatory healthcare monitoring which can serve as an enhanced alternative to the existing portable systems. All hardware components along with vital processes that are performed during the image acquisition, are presented in details. Initially, the design of the proposed 2-D phased array transducer is introduced and its performance is evaluated. Secondly, all hardware components of the system are explicitly presented and finally a software-based methodology for image enhancement that is based in image fusion and a super - resolution technique is described. The imaging quality of the designed transducer is investigated through simulations using FIELD II. Additionally, preliminary simulation results of the applied methodology for 3D images, show significant image quality improvement, especially in the regions where recording from all transducers was possible.","PeriodicalId":422807,"journal":{"name":"2015 IEEE 15th International Conference on Bioinformatics and Bioengineering (BIBE)","volume":"320 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Designing of a low-cost, volumetric multi — Transducer phased array ultrasound system\",\"authors\":\"Michail Tsakalakis, N. Bourbakis\",\"doi\":\"10.1109/BIBE.2015.7367624\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There is an undisputed need for increased portability and flexibility in diagnostic ultrasound imaging due to the continuously evolving point of care (POC) clinical applications. In order to meet this growing need numerous portable ultrasound systems have been proposed. The design of portable systems is a very challenging task, especially for volumetric imaging system which utilize transducers with hundreds and thousands of elements. This study presents a new low-cost, portable volumetric ultrasound system for ambulatory healthcare monitoring which can serve as an enhanced alternative to the existing portable systems. All hardware components along with vital processes that are performed during the image acquisition, are presented in details. Initially, the design of the proposed 2-D phased array transducer is introduced and its performance is evaluated. Secondly, all hardware components of the system are explicitly presented and finally a software-based methodology for image enhancement that is based in image fusion and a super - resolution technique is described. The imaging quality of the designed transducer is investigated through simulations using FIELD II. Additionally, preliminary simulation results of the applied methodology for 3D images, show significant image quality improvement, especially in the regions where recording from all transducers was possible.\",\"PeriodicalId\":422807,\"journal\":{\"name\":\"2015 IEEE 15th International Conference on Bioinformatics and Bioengineering (BIBE)\",\"volume\":\"320 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 15th International Conference on Bioinformatics and Bioengineering (BIBE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIBE.2015.7367624\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 15th International Conference on Bioinformatics and Bioengineering (BIBE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIBE.2015.7367624","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

由于护理点(POC)临床应用的不断发展,诊断超声成像的便携性和灵活性无可争议。为了满足这种日益增长的需求,已经提出了许多便携式超声系统。便携式系统的设计是一项非常具有挑战性的任务,特别是对于使用成百上千个元件的传感器的体积成像系统。本研究提出了一种新的低成本、便携式容积超声系统,用于门诊医疗监测,可以作为现有便携式系统的增强替代方案。详细介绍了所有硬件组件以及在图像采集期间执行的重要进程。首先介绍了二维相控阵换能器的设计,并对其性能进行了评价。其次,详细介绍了系统的硬件组成,最后介绍了一种基于图像融合和超分辨率技术的基于软件的图像增强方法。利用FIELD II仿真软件对所设计换能器的成像质量进行了研究。此外,3D图像应用方法的初步模拟结果显示,图像质量显著提高,特别是在可以从所有换能器记录的区域。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Designing of a low-cost, volumetric multi — Transducer phased array ultrasound system
There is an undisputed need for increased portability and flexibility in diagnostic ultrasound imaging due to the continuously evolving point of care (POC) clinical applications. In order to meet this growing need numerous portable ultrasound systems have been proposed. The design of portable systems is a very challenging task, especially for volumetric imaging system which utilize transducers with hundreds and thousands of elements. This study presents a new low-cost, portable volumetric ultrasound system for ambulatory healthcare monitoring which can serve as an enhanced alternative to the existing portable systems. All hardware components along with vital processes that are performed during the image acquisition, are presented in details. Initially, the design of the proposed 2-D phased array transducer is introduced and its performance is evaluated. Secondly, all hardware components of the system are explicitly presented and finally a software-based methodology for image enhancement that is based in image fusion and a super - resolution technique is described. The imaging quality of the designed transducer is investigated through simulations using FIELD II. Additionally, preliminary simulation results of the applied methodology for 3D images, show significant image quality improvement, especially in the regions where recording from all transducers was possible.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信