J. Da Silva Filho, A. Rocco, A. S. Onuki, L. Ferrara, J. M. Camargo
{"title":"电力系统事故分析的副一致逻辑应用","authors":"J. Da Silva Filho, A. Rocco, A. S. Onuki, L. Ferrara, J. M. Camargo","doi":"10.1109/ISAP.2007.4441603","DOIUrl":null,"url":null,"abstract":"In this paper we present paraconsistent logic application at electric power system contingency analysis with risks identification. Para-consistent Logic is a non-classic logic whose foundations allow for the treatment of contradictions without invalidating the conclusions through algorithms named PANs - para-consistent analysis nodes. In the equations of the PANs are calculated signals representing restrictions, risks and configurations of electric power systems networks. The \"pre- Fault state\" represented by the resulting evidence degree from PAN is evaluated together with the \"post-fault\" information in a contingency evaluation. In that way the occurrence type and their parameters are classified by PANet with the purpose of offering an optimized re-establishment sequence to the power system. This method is being validated through off-line tests applied at the Eletropaulo-Eletricidade de Sao Paulo, an electric power distribution utility company of Sao Paulo state, Brazil, which has a distribution network and a model substation of medium range.","PeriodicalId":320068,"journal":{"name":"2007 International Conference on Intelligent Systems Applications to Power Systems","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Electric Power Systems Contingencies Analysis by Paraconsistent Logic Application\",\"authors\":\"J. Da Silva Filho, A. Rocco, A. S. Onuki, L. Ferrara, J. M. Camargo\",\"doi\":\"10.1109/ISAP.2007.4441603\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper we present paraconsistent logic application at electric power system contingency analysis with risks identification. Para-consistent Logic is a non-classic logic whose foundations allow for the treatment of contradictions without invalidating the conclusions through algorithms named PANs - para-consistent analysis nodes. In the equations of the PANs are calculated signals representing restrictions, risks and configurations of electric power systems networks. The \\\"pre- Fault state\\\" represented by the resulting evidence degree from PAN is evaluated together with the \\\"post-fault\\\" information in a contingency evaluation. In that way the occurrence type and their parameters are classified by PANet with the purpose of offering an optimized re-establishment sequence to the power system. This method is being validated through off-line tests applied at the Eletropaulo-Eletricidade de Sao Paulo, an electric power distribution utility company of Sao Paulo state, Brazil, which has a distribution network and a model substation of medium range.\",\"PeriodicalId\":320068,\"journal\":{\"name\":\"2007 International Conference on Intelligent Systems Applications to Power Systems\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 International Conference on Intelligent Systems Applications to Power Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISAP.2007.4441603\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 International Conference on Intelligent Systems Applications to Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAP.2007.4441603","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
摘要
本文介绍了副一致逻辑在电力系统事故分析和风险识别中的应用。准一致逻辑是一种非经典逻辑,其基础允许通过称为pan(准一致分析节点)的算法来处理矛盾,而不会使结论无效。在pan的方程中,计算出的信号表示电力系统网络的限制、风险和配置。在权变评估中,由PAN得出的证据程度所代表的“前故障状态”与“后故障”信息一起进行评估。通过PANet对故障类型及其参数进行分类,为电力系统提供优化的重建顺序。该方法正在巴西圣保罗州的配电公司Eletropaulo-Eletricidade de Sao Paulo进行离线试验,该公司拥有一个配电网络和一个中等距离的模型变电站。
Electric Power Systems Contingencies Analysis by Paraconsistent Logic Application
In this paper we present paraconsistent logic application at electric power system contingency analysis with risks identification. Para-consistent Logic is a non-classic logic whose foundations allow for the treatment of contradictions without invalidating the conclusions through algorithms named PANs - para-consistent analysis nodes. In the equations of the PANs are calculated signals representing restrictions, risks and configurations of electric power systems networks. The "pre- Fault state" represented by the resulting evidence degree from PAN is evaluated together with the "post-fault" information in a contingency evaluation. In that way the occurrence type and their parameters are classified by PANet with the purpose of offering an optimized re-establishment sequence to the power system. This method is being validated through off-line tests applied at the Eletropaulo-Eletricidade de Sao Paulo, an electric power distribution utility company of Sao Paulo state, Brazil, which has a distribution network and a model substation of medium range.