{"title":"基于电机方电流特征分析的异步电动机定子绕组故障检测","authors":"V. Fernão Pires, D. Foito, J. Martins, A. Pires","doi":"10.1109/POWERENG.2015.7266369","DOIUrl":null,"url":null,"abstract":"In this paper the short-circuit fault inter-turn on the stator of an induction motor is analysed by an online diagnostic method. For the diagnostic method it is proposed the motor square current signature analysis (MSCSA). This method uses the results of spectral analysis of the instantaneous square stator current. The effects of stator square current spectrum are described and the related frequencies determined. This method is similar to the instantaneous power signature analysis, however has the advantage of just require one current sensor. Several simulation and experimental results are presented in order to illustrate the characteristics of the proposed method.","PeriodicalId":334135,"journal":{"name":"2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":"{\"title\":\"Detection of stator winding fault in induction motors using a motor square current signature analysis (MSCSA)\",\"authors\":\"V. Fernão Pires, D. Foito, J. Martins, A. Pires\",\"doi\":\"10.1109/POWERENG.2015.7266369\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper the short-circuit fault inter-turn on the stator of an induction motor is analysed by an online diagnostic method. For the diagnostic method it is proposed the motor square current signature analysis (MSCSA). This method uses the results of spectral analysis of the instantaneous square stator current. The effects of stator square current spectrum are described and the related frequencies determined. This method is similar to the instantaneous power signature analysis, however has the advantage of just require one current sensor. Several simulation and experimental results are presented in order to illustrate the characteristics of the proposed method.\",\"PeriodicalId\":334135,\"journal\":{\"name\":\"2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2015.7266369\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 5th International Conference on Power Engineering, Energy and Electrical Drives (POWERENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2015.7266369","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Detection of stator winding fault in induction motors using a motor square current signature analysis (MSCSA)
In this paper the short-circuit fault inter-turn on the stator of an induction motor is analysed by an online diagnostic method. For the diagnostic method it is proposed the motor square current signature analysis (MSCSA). This method uses the results of spectral analysis of the instantaneous square stator current. The effects of stator square current spectrum are described and the related frequencies determined. This method is similar to the instantaneous power signature analysis, however has the advantage of just require one current sensor. Several simulation and experimental results are presented in order to illustrate the characteristics of the proposed method.