{"title":"分子筛对直流放电/室温FAF CO激光器瞬态输出衰减和激光参数的影响","authors":"Y. Kodama, H. Sato","doi":"10.1109/CLEOE.1998.719506","DOIUrl":null,"url":null,"abstract":"The output power tends to transiently decrease with discharge time in a dc electrically pumped fast axial-flow (FAF) CO laser. This output reduction is mainly caused by both the temperature rise of gas mixture and deactivation of the excited CO molecule due to its dissociation into CO2 and O2 molecules.1 Especially, the latter seems to be predominant in the room temperature operated FAF CO laser system. The gas temperature rise due to the discharge can be compensated by fast gas-circulation through a heat exchanger along with either ethanol/dry ice coolants (or liquid nitrogen at subroom temperature operation) , whereas the CO2 molecules generated through the discharge process cannot be avoided at room temperature operation, though, it is well trapped with a cold trap of liquid nitrogen. Thus, we shall try to recover the output reduction transiently induced above by adsorbing the generated CO2 molecules by molecular sieve for the room temperature operation together with theoretical explanation. In addition, we shall also examine how the laser parameters such as the small-signal gain γ0.v saturation intensity Is and a measure of partial homogeneity m are influenced with insertion of molecular sieve.","PeriodicalId":404067,"journal":{"name":"CLEO/Europe Conference on Lasers and Electro-Optics","volume":"335 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Molecular Sieve on Transient Output-Reduction and Laser Parameters in DC Discharged/Room Temperature Operated FAF CO Laser\",\"authors\":\"Y. Kodama, H. Sato\",\"doi\":\"10.1109/CLEOE.1998.719506\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The output power tends to transiently decrease with discharge time in a dc electrically pumped fast axial-flow (FAF) CO laser. This output reduction is mainly caused by both the temperature rise of gas mixture and deactivation of the excited CO molecule due to its dissociation into CO2 and O2 molecules.1 Especially, the latter seems to be predominant in the room temperature operated FAF CO laser system. The gas temperature rise due to the discharge can be compensated by fast gas-circulation through a heat exchanger along with either ethanol/dry ice coolants (or liquid nitrogen at subroom temperature operation) , whereas the CO2 molecules generated through the discharge process cannot be avoided at room temperature operation, though, it is well trapped with a cold trap of liquid nitrogen. Thus, we shall try to recover the output reduction transiently induced above by adsorbing the generated CO2 molecules by molecular sieve for the room temperature operation together with theoretical explanation. In addition, we shall also examine how the laser parameters such as the small-signal gain γ0.v saturation intensity Is and a measure of partial homogeneity m are influenced with insertion of molecular sieve.\",\"PeriodicalId\":404067,\"journal\":{\"name\":\"CLEO/Europe Conference on Lasers and Electro-Optics\",\"volume\":\"335 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CLEO/Europe Conference on Lasers and Electro-Optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CLEOE.1998.719506\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CLEO/Europe Conference on Lasers and Electro-Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CLEOE.1998.719506","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of Molecular Sieve on Transient Output-Reduction and Laser Parameters in DC Discharged/Room Temperature Operated FAF CO Laser
The output power tends to transiently decrease with discharge time in a dc electrically pumped fast axial-flow (FAF) CO laser. This output reduction is mainly caused by both the temperature rise of gas mixture and deactivation of the excited CO molecule due to its dissociation into CO2 and O2 molecules.1 Especially, the latter seems to be predominant in the room temperature operated FAF CO laser system. The gas temperature rise due to the discharge can be compensated by fast gas-circulation through a heat exchanger along with either ethanol/dry ice coolants (or liquid nitrogen at subroom temperature operation) , whereas the CO2 molecules generated through the discharge process cannot be avoided at room temperature operation, though, it is well trapped with a cold trap of liquid nitrogen. Thus, we shall try to recover the output reduction transiently induced above by adsorbing the generated CO2 molecules by molecular sieve for the room temperature operation together with theoretical explanation. In addition, we shall also examine how the laser parameters such as the small-signal gain γ0.v saturation intensity Is and a measure of partial homogeneity m are influenced with insertion of molecular sieve.