{"title":"风湿性二尖瓣病","authors":"L. Shapiro, A. Kenny","doi":"10.1201/9781315138800-3","DOIUrl":null,"url":null,"abstract":".. Objectives: To study the early outcomes of mitral valve replacement with a mechanical prosthesis is patients with rheumatic mitral valvular disease. Study Design: Retrospective Observational study. Setting: Punjab Institute of Cardiology, Lahore and Rawalpindi Institute of Cardiology, Rawalpindi. Period: From August 2014 to August 2017. Material & Methods: Consecutive patients who underwent mitral valve replacement for a rheumatic pathology were included in the study. Patients undergoing a redo surgery, those with concomitant aortic valve intervention, coronary artery bypass grafting and emergency procedures were excluded from the study. Results: Of the 104 patients included in the study, 58 (56.2%) were female patients. The mean age of the patients was 35 ± 12.36 years (median 33 years). Sixty (58.5%) had hypertension and 22 (21.28%) had diabetes. Mitral valve stenosis was the main pathology in 84 (80.7%). Severe pulmonary hypertension was recorded in 16 (15%) patients. The mean preoperative Tricuspid Valve Pressure Gradient (TVPG) was 55.33 ± 18.35 mmHg. The mean cross clamp time was 45.33 ± 12.32 minutes. The postoperative tricuspid valve pressure gradient came down to 31.5 ± 12.21 mmHg. No patients had acute renal injury, pulmonary complications or re-exploration for bleeding. Perioperative mortality was 4 (3.75%). Conclusion: Rheumatic valvular disease is still prevalent in our part of the world. Most of the patients with rheumatic heart disease will end up with replacement of the valve. Replacement with a mechanical prosthesis has favorable early outcomes.","PeriodicalId":357091,"journal":{"name":"Cardiac Ultrasound","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rheumatic Mitral Valve Disease\",\"authors\":\"L. Shapiro, A. Kenny\",\"doi\":\"10.1201/9781315138800-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\".. Objectives: To study the early outcomes of mitral valve replacement with a mechanical prosthesis is patients with rheumatic mitral valvular disease. Study Design: Retrospective Observational study. Setting: Punjab Institute of Cardiology, Lahore and Rawalpindi Institute of Cardiology, Rawalpindi. Period: From August 2014 to August 2017. Material & Methods: Consecutive patients who underwent mitral valve replacement for a rheumatic pathology were included in the study. Patients undergoing a redo surgery, those with concomitant aortic valve intervention, coronary artery bypass grafting and emergency procedures were excluded from the study. Results: Of the 104 patients included in the study, 58 (56.2%) were female patients. The mean age of the patients was 35 ± 12.36 years (median 33 years). Sixty (58.5%) had hypertension and 22 (21.28%) had diabetes. Mitral valve stenosis was the main pathology in 84 (80.7%). Severe pulmonary hypertension was recorded in 16 (15%) patients. The mean preoperative Tricuspid Valve Pressure Gradient (TVPG) was 55.33 ± 18.35 mmHg. The mean cross clamp time was 45.33 ± 12.32 minutes. The postoperative tricuspid valve pressure gradient came down to 31.5 ± 12.21 mmHg. No patients had acute renal injury, pulmonary complications or re-exploration for bleeding. Perioperative mortality was 4 (3.75%). Conclusion: Rheumatic valvular disease is still prevalent in our part of the world. Most of the patients with rheumatic heart disease will end up with replacement of the valve. Replacement with a mechanical prosthesis has favorable early outcomes.\",\"PeriodicalId\":357091,\"journal\":{\"name\":\"Cardiac Ultrasound\",\"volume\":\"79 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiac Ultrasound\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1201/9781315138800-3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiac Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1201/9781315138800-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
.. Objectives: To study the early outcomes of mitral valve replacement with a mechanical prosthesis is patients with rheumatic mitral valvular disease. Study Design: Retrospective Observational study. Setting: Punjab Institute of Cardiology, Lahore and Rawalpindi Institute of Cardiology, Rawalpindi. Period: From August 2014 to August 2017. Material & Methods: Consecutive patients who underwent mitral valve replacement for a rheumatic pathology were included in the study. Patients undergoing a redo surgery, those with concomitant aortic valve intervention, coronary artery bypass grafting and emergency procedures were excluded from the study. Results: Of the 104 patients included in the study, 58 (56.2%) were female patients. The mean age of the patients was 35 ± 12.36 years (median 33 years). Sixty (58.5%) had hypertension and 22 (21.28%) had diabetes. Mitral valve stenosis was the main pathology in 84 (80.7%). Severe pulmonary hypertension was recorded in 16 (15%) patients. The mean preoperative Tricuspid Valve Pressure Gradient (TVPG) was 55.33 ± 18.35 mmHg. The mean cross clamp time was 45.33 ± 12.32 minutes. The postoperative tricuspid valve pressure gradient came down to 31.5 ± 12.21 mmHg. No patients had acute renal injury, pulmonary complications or re-exploration for bleeding. Perioperative mortality was 4 (3.75%). Conclusion: Rheumatic valvular disease is still prevalent in our part of the world. Most of the patients with rheumatic heart disease will end up with replacement of the valve. Replacement with a mechanical prosthesis has favorable early outcomes.