Sang Won Park, S. Hwang, Jang-Woo Ryu, S. Hong, M. Sung
{"title":"非制冷红外测热计传感器读出IC的偏置偏置校正技术","authors":"Sang Won Park, S. Hwang, Jang-Woo Ryu, S. Hong, M. Sung","doi":"10.1109/EDSSC.2005.1635378","DOIUrl":null,"url":null,"abstract":"Infrared bolometer sensor's variation is detected by voltage drop between a reference resistor and a bolometer resistor in this architecture. One of the serious problems in this architecture is that these resistors value has a process variation. So common-mode level could be different from expectation value in room temperature. Different common-mode level could lead to wrong output at the end of readout circuit. We suggest useful method to solve this problem. Difference correction using capacitor has reduced CM level difference to 88.5 % for I MΩ bolometer and reference resistor's 10 % variation.","PeriodicalId":429314,"journal":{"name":"2005 IEEE Conference on Electron Devices and Solid-State Circuits","volume":"188 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Bias Offset Correction Technique For Uncooled Infrared Bolometer Sensor Readout IC\",\"authors\":\"Sang Won Park, S. Hwang, Jang-Woo Ryu, S. Hong, M. Sung\",\"doi\":\"10.1109/EDSSC.2005.1635378\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Infrared bolometer sensor's variation is detected by voltage drop between a reference resistor and a bolometer resistor in this architecture. One of the serious problems in this architecture is that these resistors value has a process variation. So common-mode level could be different from expectation value in room temperature. Different common-mode level could lead to wrong output at the end of readout circuit. We suggest useful method to solve this problem. Difference correction using capacitor has reduced CM level difference to 88.5 % for I MΩ bolometer and reference resistor's 10 % variation.\",\"PeriodicalId\":429314,\"journal\":{\"name\":\"2005 IEEE Conference on Electron Devices and Solid-State Circuits\",\"volume\":\"188 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 IEEE Conference on Electron Devices and Solid-State Circuits\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EDSSC.2005.1635378\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE Conference on Electron Devices and Solid-State Circuits","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDSSC.2005.1635378","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Bias Offset Correction Technique For Uncooled Infrared Bolometer Sensor Readout IC
Infrared bolometer sensor's variation is detected by voltage drop between a reference resistor and a bolometer resistor in this architecture. One of the serious problems in this architecture is that these resistors value has a process variation. So common-mode level could be different from expectation value in room temperature. Different common-mode level could lead to wrong output at the end of readout circuit. We suggest useful method to solve this problem. Difference correction using capacitor has reduced CM level difference to 88.5 % for I MΩ bolometer and reference resistor's 10 % variation.