不同渗透水平下的低压光伏并网发电研究

Z. Rajab, A. Asheibi, M. Almaktar, A. Khalil, A. Elbreki, F. Mohamed
{"title":"不同渗透水平下的低压光伏并网发电研究","authors":"Z. Rajab, A. Asheibi, M. Almaktar, A. Khalil, A. Elbreki, F. Mohamed","doi":"10.1109/IREC56325.2022.10002140","DOIUrl":null,"url":null,"abstract":"The existence of abundant and free solar energy has contributed to the rapid development of PV systems, particularly rooftop installations and solar plants construction at transmission and distribution levels. Nevertheless, high penetration level of PV systems at distribution network level could potentially lead to abnormal operation of network. At steady state, the impacts are experienced on voltage (level, profile, stability and drop), line losses, equipment loading, etc. In this paper, a part of Benghazi distribution network is simulated by NEPLAN software. A real data for load and weather were used to simulate the real condition. The paper studies the impacts by comparing the behavior of the distribution grid without PV installations and with PV systems installed with different penetration levels (0%, 50%, 65% and 75%). The results generally showed that the installation of rooftop PV systems caused improvement in voltage profile, decreasing equipment’s (transformers and lines/feeders) loading and line losses. On the other hand, extensive deployment of PV capacity will cause an increase in equipment’s loading. The high penetration of PV systems will also affect the voltage profile, voltage level, and losses. From the results, the allowable penetration percentage (Hosting capacity) for the simulated network must not exceed 65%.","PeriodicalId":115939,"journal":{"name":"2022 13th International Renewable Energy Congress (IREC)","volume":"218 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Examination of Low Voltage Grid- Connected PV Generation Under Different Penetration Levels\",\"authors\":\"Z. Rajab, A. Asheibi, M. Almaktar, A. Khalil, A. Elbreki, F. Mohamed\",\"doi\":\"10.1109/IREC56325.2022.10002140\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The existence of abundant and free solar energy has contributed to the rapid development of PV systems, particularly rooftop installations and solar plants construction at transmission and distribution levels. Nevertheless, high penetration level of PV systems at distribution network level could potentially lead to abnormal operation of network. At steady state, the impacts are experienced on voltage (level, profile, stability and drop), line losses, equipment loading, etc. In this paper, a part of Benghazi distribution network is simulated by NEPLAN software. A real data for load and weather were used to simulate the real condition. The paper studies the impacts by comparing the behavior of the distribution grid without PV installations and with PV systems installed with different penetration levels (0%, 50%, 65% and 75%). The results generally showed that the installation of rooftop PV systems caused improvement in voltage profile, decreasing equipment’s (transformers and lines/feeders) loading and line losses. On the other hand, extensive deployment of PV capacity will cause an increase in equipment’s loading. The high penetration of PV systems will also affect the voltage profile, voltage level, and losses. From the results, the allowable penetration percentage (Hosting capacity) for the simulated network must not exceed 65%.\",\"PeriodicalId\":115939,\"journal\":{\"name\":\"2022 13th International Renewable Energy Congress (IREC)\",\"volume\":\"218 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 13th International Renewable Energy Congress (IREC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IREC56325.2022.10002140\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 13th International Renewable Energy Congress (IREC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IREC56325.2022.10002140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

丰富和免费的太阳能的存在促进了光伏系统的迅速发展,特别是在输电和配电一级的屋顶安装和太阳能发电厂的建设。然而,光伏系统在配电网层面的高渗透水平可能会导致电网的异常运行。在稳定状态下,会对电压(电平、轮廓、稳定性和降)、线路损耗、设备负载等产生影响。本文利用NEPLAN软件对班加西配电网的一部分进行了仿真。采用实际的负荷和天气数据来模拟实际工况。本文通过比较不安装光伏和安装不同渗透率(0%、50%、65%和75%)的光伏系统对配电网的影响进行了研究。结果普遍表明,屋顶光伏系统的安装改善了电压分布,减少了设备(变压器和线路/馈线)的负载和线路损耗。另一方面,光伏容量的广泛部署将导致设备负荷的增加。光伏系统的高渗透率也会影响电压分布、电压水平和损耗。从结果来看,模拟网络的允许渗透百分比(主机容量)不得超过65%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Examination of Low Voltage Grid- Connected PV Generation Under Different Penetration Levels
The existence of abundant and free solar energy has contributed to the rapid development of PV systems, particularly rooftop installations and solar plants construction at transmission and distribution levels. Nevertheless, high penetration level of PV systems at distribution network level could potentially lead to abnormal operation of network. At steady state, the impacts are experienced on voltage (level, profile, stability and drop), line losses, equipment loading, etc. In this paper, a part of Benghazi distribution network is simulated by NEPLAN software. A real data for load and weather were used to simulate the real condition. The paper studies the impacts by comparing the behavior of the distribution grid without PV installations and with PV systems installed with different penetration levels (0%, 50%, 65% and 75%). The results generally showed that the installation of rooftop PV systems caused improvement in voltage profile, decreasing equipment’s (transformers and lines/feeders) loading and line losses. On the other hand, extensive deployment of PV capacity will cause an increase in equipment’s loading. The high penetration of PV systems will also affect the voltage profile, voltage level, and losses. From the results, the allowable penetration percentage (Hosting capacity) for the simulated network must not exceed 65%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信