{"title":"基于ar和MED的冷却风扇轴承诊断","authors":"Chaoqin Liu, Xue Zhou, Shuai Yang, Wei Liang, Q. Miao","doi":"10.1109/ICQR2MSE.2012.6246310","DOIUrl":null,"url":null,"abstract":"To monitor the initial failure of cooling fan's rolling bearing, this paper reviews the theory of autoregressive (AR) model and the minimum entropy deconvolution (MED) filtering technique. The AR method can remove the deterministic components of the original signal, and the MED filter could reduce the effect of the transmission path. These two filtering techniques were combined in this paper to pre-process the rolling bearing's vibration signal, and then the envelope spectrum of the residual signal was analyzed. The method leads to efficient filtering result.","PeriodicalId":401503,"journal":{"name":"2012 International Conference on Quality, Reliability, Risk, Maintenance, and Safety Engineering","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Cooling fan bearing diagnosis based on AR& MED\",\"authors\":\"Chaoqin Liu, Xue Zhou, Shuai Yang, Wei Liang, Q. Miao\",\"doi\":\"10.1109/ICQR2MSE.2012.6246310\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To monitor the initial failure of cooling fan's rolling bearing, this paper reviews the theory of autoregressive (AR) model and the minimum entropy deconvolution (MED) filtering technique. The AR method can remove the deterministic components of the original signal, and the MED filter could reduce the effect of the transmission path. These two filtering techniques were combined in this paper to pre-process the rolling bearing's vibration signal, and then the envelope spectrum of the residual signal was analyzed. The method leads to efficient filtering result.\",\"PeriodicalId\":401503,\"journal\":{\"name\":\"2012 International Conference on Quality, Reliability, Risk, Maintenance, and Safety Engineering\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Quality, Reliability, Risk, Maintenance, and Safety Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICQR2MSE.2012.6246310\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Quality, Reliability, Risk, Maintenance, and Safety Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICQR2MSE.2012.6246310","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
To monitor the initial failure of cooling fan's rolling bearing, this paper reviews the theory of autoregressive (AR) model and the minimum entropy deconvolution (MED) filtering technique. The AR method can remove the deterministic components of the original signal, and the MED filter could reduce the effect of the transmission path. These two filtering techniques were combined in this paper to pre-process the rolling bearing's vibration signal, and then the envelope spectrum of the residual signal was analyzed. The method leads to efficient filtering result.