三维幻影测量验证相控阵在深部肿瘤照射中的应用

M. Melek, A. Anderson, J. Conway, B. H. Brown
{"title":"三维幻影测量验证相控阵在深部肿瘤照射中的应用","authors":"M. Melek, A. Anderson, J. Conway, B. H. Brown","doi":"10.1109/EUMA.1983.333299","DOIUrl":null,"url":null,"abstract":"The feasibility of using phased arrays for focused microwave hyperthermia is examined. A prototype system consisting of a semi-elliptic array of six 2.45GHz dipole antennas surrounding a homogeneous cylindrical body with the dielectric properties of the human lungs, and a linear array of five elements parallel to the axis of the body has been used to verify computational simulations of the same configuration. Microwave field intensities measured within the phantom indicate good agreement with theoretical predictions. A computer simulation for a different configuration is presented in order to show the inherent flexibility of the phased array applicator system. The results confirm the possibility of using phased arrays for induced localised hyperthermia for deep-seated tumour destruction provided that temperature monitoring is available.","PeriodicalId":105436,"journal":{"name":"1983 13th European Microwave Conference","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1983-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Three Dimensional Phantom Measurements Validating the Use of Phased Arrays for Deep-Seated Tumour Irradiation\",\"authors\":\"M. Melek, A. Anderson, J. Conway, B. H. Brown\",\"doi\":\"10.1109/EUMA.1983.333299\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The feasibility of using phased arrays for focused microwave hyperthermia is examined. A prototype system consisting of a semi-elliptic array of six 2.45GHz dipole antennas surrounding a homogeneous cylindrical body with the dielectric properties of the human lungs, and a linear array of five elements parallel to the axis of the body has been used to verify computational simulations of the same configuration. Microwave field intensities measured within the phantom indicate good agreement with theoretical predictions. A computer simulation for a different configuration is presented in order to show the inherent flexibility of the phased array applicator system. The results confirm the possibility of using phased arrays for induced localised hyperthermia for deep-seated tumour destruction provided that temperature monitoring is available.\",\"PeriodicalId\":105436,\"journal\":{\"name\":\"1983 13th European Microwave Conference\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1983 13th European Microwave Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUMA.1983.333299\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1983 13th European Microwave Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMA.1983.333299","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

研究了相控阵用于聚焦微波热疗的可行性。一个由六个2.45GHz偶极子天线组成的半椭圆阵列围绕一个具有人体肺部介电特性的均匀圆柱体,以及一个平行于人体轴线的五元线性阵列组成的原型系统已经被用来验证相同配置的计算模拟。在模体内测量的微波场强度与理论预测一致。为了显示相控阵应用系统固有的灵活性,给出了一种不同配置的计算机仿真。该结果证实了在温度监测可用的情况下,使用相控阵诱导局部热疗来破坏深层肿瘤的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Three Dimensional Phantom Measurements Validating the Use of Phased Arrays for Deep-Seated Tumour Irradiation
The feasibility of using phased arrays for focused microwave hyperthermia is examined. A prototype system consisting of a semi-elliptic array of six 2.45GHz dipole antennas surrounding a homogeneous cylindrical body with the dielectric properties of the human lungs, and a linear array of five elements parallel to the axis of the body has been used to verify computational simulations of the same configuration. Microwave field intensities measured within the phantom indicate good agreement with theoretical predictions. A computer simulation for a different configuration is presented in order to show the inherent flexibility of the phased array applicator system. The results confirm the possibility of using phased arrays for induced localised hyperthermia for deep-seated tumour destruction provided that temperature monitoring is available.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信