{"title":"减小尺寸测量用三维硅基微探头的探头球直径","authors":"N. Ferreira, A. Brennecke, A. Dietzel, S. Büttgenbach, T. Krah, D. Metz, K. Kniel, F. Hartig","doi":"10.1109/ICSENST.2013.6727663","DOIUrl":null,"url":null,"abstract":"Microprobing systems based on silicon force sensors allow accurate force and displacement measurements in the range of several μN or μm. Due to the high sensitive diffused piezoresistors and an appropriate electrical circuitry, these probing systems enable tactile measurement without leaving scratches on the probed surfaces. To probe microstructures on workpieces, probes with probe balls as small as possible are sought. Mostly, commercial microprobes have probe balls with diameters of 120 μm or larger. In this work, microprobes with probe ball diameters down to 50 μm are presented and characterized in detail. In order to verify the performance of these new microprobes, measurements have been carried out to characterize both their mechanical behavior and their sensitivity. These properties have been extensively analyzed for different sensor designs and probe ball diameters. For instance, microprobes with probe ball diameters of 50 μm have a stiffness of about 0.637 mN/μm in X-Y and about 20.023 mN/μm in Z directions of the probe. The sensitivity amounts to 1.174 mV/V/μm and 20.478 mV/V/μm in X-Y and Z directions, respectively. The results presented encourage a new generation of microprobes to be used in dimensional metrology.","PeriodicalId":374655,"journal":{"name":"2013 Seventh International Conference on Sensing Technology (ICST)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Reducing the probe ball diameters of 3D silicon-based microprobes for dimensional metrology\",\"authors\":\"N. Ferreira, A. Brennecke, A. Dietzel, S. Büttgenbach, T. Krah, D. Metz, K. Kniel, F. Hartig\",\"doi\":\"10.1109/ICSENST.2013.6727663\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Microprobing systems based on silicon force sensors allow accurate force and displacement measurements in the range of several μN or μm. Due to the high sensitive diffused piezoresistors and an appropriate electrical circuitry, these probing systems enable tactile measurement without leaving scratches on the probed surfaces. To probe microstructures on workpieces, probes with probe balls as small as possible are sought. Mostly, commercial microprobes have probe balls with diameters of 120 μm or larger. In this work, microprobes with probe ball diameters down to 50 μm are presented and characterized in detail. In order to verify the performance of these new microprobes, measurements have been carried out to characterize both their mechanical behavior and their sensitivity. These properties have been extensively analyzed for different sensor designs and probe ball diameters. For instance, microprobes with probe ball diameters of 50 μm have a stiffness of about 0.637 mN/μm in X-Y and about 20.023 mN/μm in Z directions of the probe. The sensitivity amounts to 1.174 mV/V/μm and 20.478 mV/V/μm in X-Y and Z directions, respectively. The results presented encourage a new generation of microprobes to be used in dimensional metrology.\",\"PeriodicalId\":374655,\"journal\":{\"name\":\"2013 Seventh International Conference on Sensing Technology (ICST)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Seventh International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2013.6727663\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Seventh International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2013.6727663","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

基于硅力传感器的微探测系统可以在几个μN或μm的范围内进行精确的力和位移测量。由于高灵敏度的扩散压阻和适当的电路,这些探测系统使触觉测量不会在探测表面留下划痕。为了探测工件上的微结构,需要寻找具有尽可能小的探测球的探针。大多数商用微探针的探针球直径为120 μm或更大。在这项工作中,探针球直径低至50 μm的微探针被提出并详细表征。为了验证这些新型微探针的性能,已经进行了测量,以表征它们的机械行为和灵敏度。对于不同的传感器设计和探头球直径,已经对这些特性进行了广泛的分析。例如,探头球直径为50 μm的微探头,其X-Y方向刚度约为0.637 mN/μm, Z方向刚度约为20.023 mN/μm。X-Y和Z方向的灵敏度分别为1.174 mV/V/μm和20.478 mV/V/μm。所提出的结果鼓励了新一代微探头在尺寸测量中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reducing the probe ball diameters of 3D silicon-based microprobes for dimensional metrology
Microprobing systems based on silicon force sensors allow accurate force and displacement measurements in the range of several μN or μm. Due to the high sensitive diffused piezoresistors and an appropriate electrical circuitry, these probing systems enable tactile measurement without leaving scratches on the probed surfaces. To probe microstructures on workpieces, probes with probe balls as small as possible are sought. Mostly, commercial microprobes have probe balls with diameters of 120 μm or larger. In this work, microprobes with probe ball diameters down to 50 μm are presented and characterized in detail. In order to verify the performance of these new microprobes, measurements have been carried out to characterize both their mechanical behavior and their sensitivity. These properties have been extensively analyzed for different sensor designs and probe ball diameters. For instance, microprobes with probe ball diameters of 50 μm have a stiffness of about 0.637 mN/μm in X-Y and about 20.023 mN/μm in Z directions of the probe. The sensitivity amounts to 1.174 mV/V/μm and 20.478 mV/V/μm in X-Y and Z directions, respectively. The results presented encourage a new generation of microprobes to be used in dimensional metrology.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信