S. Sedghi, A. Dastfan, A. Ahmadyfard, A. Akbarzadeh Kalat
{"title":"基于LCL网格滤波器的四腿有源电力滤波器自适应控制策略","authors":"S. Sedghi, A. Dastfan, A. Ahmadyfard, A. Akbarzadeh Kalat","doi":"10.1109/PEDSTC.2017.7910383","DOIUrl":null,"url":null,"abstract":"This paper presents an indirect adaptive self-tuning regulator for a four-leg active power filter with a high order grid filter which is used for reactive power and unbalanced and harmonic currents. The proposed scheme can guarantee a good performance in the presence of large signal changes in the operating point, uncertainty of the LCL filter components and effect of imperfect modeling. Also a decoupling factor is used for improving the accuracy of the control scheme. The switching of the converter is performed using indirect control scheme which control the grid currents instead of the converter currents. The simulation results demonstrate the effectiveness of the proposed method.","PeriodicalId":414828,"journal":{"name":"2017 8th Power Electronics, Drive Systems & Technologies Conference (PEDSTC)","volume":"199 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Adaptive control strategy of four-leg active power filter with LCL grid filter\",\"authors\":\"S. Sedghi, A. Dastfan, A. Ahmadyfard, A. Akbarzadeh Kalat\",\"doi\":\"10.1109/PEDSTC.2017.7910383\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an indirect adaptive self-tuning regulator for a four-leg active power filter with a high order grid filter which is used for reactive power and unbalanced and harmonic currents. The proposed scheme can guarantee a good performance in the presence of large signal changes in the operating point, uncertainty of the LCL filter components and effect of imperfect modeling. Also a decoupling factor is used for improving the accuracy of the control scheme. The switching of the converter is performed using indirect control scheme which control the grid currents instead of the converter currents. The simulation results demonstrate the effectiveness of the proposed method.\",\"PeriodicalId\":414828,\"journal\":{\"name\":\"2017 8th Power Electronics, Drive Systems & Technologies Conference (PEDSTC)\",\"volume\":\"199 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 8th Power Electronics, Drive Systems & Technologies Conference (PEDSTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDSTC.2017.7910383\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 8th Power Electronics, Drive Systems & Technologies Conference (PEDSTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDSTC.2017.7910383","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Adaptive control strategy of four-leg active power filter with LCL grid filter
This paper presents an indirect adaptive self-tuning regulator for a four-leg active power filter with a high order grid filter which is used for reactive power and unbalanced and harmonic currents. The proposed scheme can guarantee a good performance in the presence of large signal changes in the operating point, uncertainty of the LCL filter components and effect of imperfect modeling. Also a decoupling factor is used for improving the accuracy of the control scheme. The switching of the converter is performed using indirect control scheme which control the grid currents instead of the converter currents. The simulation results demonstrate the effectiveness of the proposed method.