新型微型FIA-ISFET集成传感器的研制

Niu Mengnian, Ding Xinfang, Tao Xiang, Lin Wei
{"title":"新型微型FIA-ISFET集成传感器的研制","authors":"Niu Mengnian, Ding Xinfang, Tao Xiang, Lin Wei","doi":"10.1109/TENCON.1995.496368","DOIUrl":null,"url":null,"abstract":"Based on the principle of flow injection analysis (FIA), this paper reports a novel micro FIA-ISFET integrated sensor. Four pairs of long-arm pH-ISFET/REFET units and symmetric Ti/Au film pseudo-reference electrodes are integrated on the chip, so that an integrated configuration of transducer and micro flow-through cell is achieved. The chip size of the sensor is 6*8mm/sup 2/. Initial experimental results indicate that the liquid can be measured driven by peristaltic pump flows with great fluency and that the amount of test sample needed in dynamic measurement is greatly reduced. The integrated sensor has quick response and its reliability and stability are considerably improved.","PeriodicalId":425138,"journal":{"name":"1995 IEEE TENCON. IEEE Region 10 International Conference on Microelectronics and VLSI. 'Asia-Pacific Microelectronics 2000'. Proceedings","volume":"648 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of a novel micro FIA-ISFET integrated sensor\",\"authors\":\"Niu Mengnian, Ding Xinfang, Tao Xiang, Lin Wei\",\"doi\":\"10.1109/TENCON.1995.496368\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Based on the principle of flow injection analysis (FIA), this paper reports a novel micro FIA-ISFET integrated sensor. Four pairs of long-arm pH-ISFET/REFET units and symmetric Ti/Au film pseudo-reference electrodes are integrated on the chip, so that an integrated configuration of transducer and micro flow-through cell is achieved. The chip size of the sensor is 6*8mm/sup 2/. Initial experimental results indicate that the liquid can be measured driven by peristaltic pump flows with great fluency and that the amount of test sample needed in dynamic measurement is greatly reduced. The integrated sensor has quick response and its reliability and stability are considerably improved.\",\"PeriodicalId\":425138,\"journal\":{\"name\":\"1995 IEEE TENCON. IEEE Region 10 International Conference on Microelectronics and VLSI. 'Asia-Pacific Microelectronics 2000'. Proceedings\",\"volume\":\"648 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1995 IEEE TENCON. IEEE Region 10 International Conference on Microelectronics and VLSI. 'Asia-Pacific Microelectronics 2000'. Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TENCON.1995.496368\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1995 IEEE TENCON. IEEE Region 10 International Conference on Microelectronics and VLSI. 'Asia-Pacific Microelectronics 2000'. Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENCON.1995.496368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

基于流动注射分析(FIA)的原理,本文报道了一种新型的微型FIA- isfet集成传感器。芯片上集成了4对长臂pH-ISFET/REFET单元和对称Ti/Au膜伪参比电极,实现了换能器和微通流池的集成配置。传感器的芯片尺寸为6*8mm/sup 2/。初步实验结果表明,在蠕动泵的驱动下,液体流动非常流畅,动态测量所需的测试样品量大大减少。集成后的传感器响应速度快,可靠性和稳定性大大提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a novel micro FIA-ISFET integrated sensor
Based on the principle of flow injection analysis (FIA), this paper reports a novel micro FIA-ISFET integrated sensor. Four pairs of long-arm pH-ISFET/REFET units and symmetric Ti/Au film pseudo-reference electrodes are integrated on the chip, so that an integrated configuration of transducer and micro flow-through cell is achieved. The chip size of the sensor is 6*8mm/sup 2/. Initial experimental results indicate that the liquid can be measured driven by peristaltic pump flows with great fluency and that the amount of test sample needed in dynamic measurement is greatly reduced. The integrated sensor has quick response and its reliability and stability are considerably improved.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信