{"title":"外部分流与内部分流的脱泵格伦","authors":"A. Elhaddad, A. Mohammed","doi":"10.4103/ejca.ejca_6_22","DOIUrl":null,"url":null,"abstract":"Background Off-pump bidirectional Glenn (BDG) operation can be associated with elevation of superior vena cava (SVC) pressure that may lead to neurological damage. Aim Off-pump BDG operation was done using either a veno-atrial shunt or external shunt to decompress SVC during clamping. Patients and methods A prospective, randomized comparative study in a single tertiary care cardiac center where 30 patients with functional single ventricle underwent off-pump BDG. Group I with a veno-atrial shunt (internal) and group E with an external shunt. Measurements and main results There was no early hospital mortality. The mean SVC pressure during clamping was 40.4±3.4 mmHg before and 28.5±3.8 mmHg after shunt opening in group I and 37.6±4.5 mmHg before and 26.4±2.1 mmHg after shunt opening in group E. The mean clamp time was 19.8±3.5 min in group I and 16.9±4.4 min in group E. The transcranial pressure gradient was 58.1±6.89 mmHg in group I, while 54.86±9.1 mmHg in group E. There were no major neurological complications apart from treatable convulsions in one (3%) case in group I and delayed recovery in one (3%) case in group E. Conclusions Off-pump BDG can be safely performed with either external or internal shunt avoiding cardiopulmonary bypass complications.","PeriodicalId":289218,"journal":{"name":"The Egyptian Journal of Cardiothoracic Anesthesia","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"External shunt versus internal shunt for off-pump Glenn\",\"authors\":\"A. Elhaddad, A. Mohammed\",\"doi\":\"10.4103/ejca.ejca_6_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background Off-pump bidirectional Glenn (BDG) operation can be associated with elevation of superior vena cava (SVC) pressure that may lead to neurological damage. Aim Off-pump BDG operation was done using either a veno-atrial shunt or external shunt to decompress SVC during clamping. Patients and methods A prospective, randomized comparative study in a single tertiary care cardiac center where 30 patients with functional single ventricle underwent off-pump BDG. Group I with a veno-atrial shunt (internal) and group E with an external shunt. Measurements and main results There was no early hospital mortality. The mean SVC pressure during clamping was 40.4±3.4 mmHg before and 28.5±3.8 mmHg after shunt opening in group I and 37.6±4.5 mmHg before and 26.4±2.1 mmHg after shunt opening in group E. The mean clamp time was 19.8±3.5 min in group I and 16.9±4.4 min in group E. The transcranial pressure gradient was 58.1±6.89 mmHg in group I, while 54.86±9.1 mmHg in group E. There were no major neurological complications apart from treatable convulsions in one (3%) case in group I and delayed recovery in one (3%) case in group E. Conclusions Off-pump BDG can be safely performed with either external or internal shunt avoiding cardiopulmonary bypass complications.\",\"PeriodicalId\":289218,\"journal\":{\"name\":\"The Egyptian Journal of Cardiothoracic Anesthesia\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Egyptian Journal of Cardiothoracic Anesthesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ejca.ejca_6_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Egyptian Journal of Cardiothoracic Anesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ejca.ejca_6_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
External shunt versus internal shunt for off-pump Glenn
Background Off-pump bidirectional Glenn (BDG) operation can be associated with elevation of superior vena cava (SVC) pressure that may lead to neurological damage. Aim Off-pump BDG operation was done using either a veno-atrial shunt or external shunt to decompress SVC during clamping. Patients and methods A prospective, randomized comparative study in a single tertiary care cardiac center where 30 patients with functional single ventricle underwent off-pump BDG. Group I with a veno-atrial shunt (internal) and group E with an external shunt. Measurements and main results There was no early hospital mortality. The mean SVC pressure during clamping was 40.4±3.4 mmHg before and 28.5±3.8 mmHg after shunt opening in group I and 37.6±4.5 mmHg before and 26.4±2.1 mmHg after shunt opening in group E. The mean clamp time was 19.8±3.5 min in group I and 16.9±4.4 min in group E. The transcranial pressure gradient was 58.1±6.89 mmHg in group I, while 54.86±9.1 mmHg in group E. There were no major neurological complications apart from treatable convulsions in one (3%) case in group I and delayed recovery in one (3%) case in group E. Conclusions Off-pump BDG can be safely performed with either external or internal shunt avoiding cardiopulmonary bypass complications.