大型水轮发电机波浪绕组内部短路故障建模与仿真

S. Hemmati, S. Shokri, S. Saied
{"title":"大型水轮发电机波浪绕组内部短路故障建模与仿真","authors":"S. Hemmati, S. Shokri, S. Saied","doi":"10.1109/POWERENG.2011.6036490","DOIUrl":null,"url":null,"abstract":"When an internal fault occurs in the wave-connected windings of salient-pole synchronous generators, the symmetry between the parallel windings is broken, and different currents flow in them since unsymmetrical magnetic linkage exists between the stator windings. The aim of this article is to present a model to investigate the internal fault currents in large hydro generators with wave windings. This model is based on a modified winding function approach, where the machine inductances are calculated directly from the machine winding distribution, and the space harmonics produced by them are also taken into account. By using the simulated internal fault data, suitable numerical protection schemes for hydro generators can be developed.","PeriodicalId":166144,"journal":{"name":"2011 International Conference on Power Engineering, Energy and Electrical Drives","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Modeling and simulation of internal short circuit faults in large hydro generators with wave windings\",\"authors\":\"S. Hemmati, S. Shokri, S. Saied\",\"doi\":\"10.1109/POWERENG.2011.6036490\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When an internal fault occurs in the wave-connected windings of salient-pole synchronous generators, the symmetry between the parallel windings is broken, and different currents flow in them since unsymmetrical magnetic linkage exists between the stator windings. The aim of this article is to present a model to investigate the internal fault currents in large hydro generators with wave windings. This model is based on a modified winding function approach, where the machine inductances are calculated directly from the machine winding distribution, and the space harmonics produced by them are also taken into account. By using the simulated internal fault data, suitable numerical protection schemes for hydro generators can be developed.\",\"PeriodicalId\":166144,\"journal\":{\"name\":\"2011 International Conference on Power Engineering, Energy and Electrical Drives\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Power Engineering, Energy and Electrical Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERENG.2011.6036490\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power Engineering, Energy and Electrical Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERENG.2011.6036490","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

当显著极同步发电机的波接绕组发生内部故障时,由于定子绕组之间存在不对称的磁连接,并联绕组之间的对称性被打破,产生不同的电流。本文的目的是建立一个模型来研究具有波浪绕组的大型水轮发电机内部故障电流。该模型基于一种改进的绕组函数方法,其中直接从机器绕组分布计算机器电感,并考虑它们产生的空间谐波。利用模拟的内部故障数据,可以制定适合水轮发电机的数值保护方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Modeling and simulation of internal short circuit faults in large hydro generators with wave windings
When an internal fault occurs in the wave-connected windings of salient-pole synchronous generators, the symmetry between the parallel windings is broken, and different currents flow in them since unsymmetrical magnetic linkage exists between the stator windings. The aim of this article is to present a model to investigate the internal fault currents in large hydro generators with wave windings. This model is based on a modified winding function approach, where the machine inductances are calculated directly from the machine winding distribution, and the space harmonics produced by them are also taken into account. By using the simulated internal fault data, suitable numerical protection schemes for hydro generators can be developed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信