在小岛屿电网中建立可持续的电力结构:多标准分析

L. Lemiale, R. Loisel, S. Bourguet, A. Roy, M. Machmoun
{"title":"在小岛屿电网中建立可持续的电力结构:多标准分析","authors":"L. Lemiale, R. Loisel, S. Bourguet, A. Roy, M. Machmoun","doi":"10.1109/OSES.2019.8867351","DOIUrl":null,"url":null,"abstract":"Islands have traditionally experienced great dependency on external energy supply and many of them opted for diesel as fuel for power generation. This study tests scenarios of different levels of renewable penetration on the French Atlantic island Ouessant, facing the general problems of the energy planning such as grid reliability, the lack of economies of scale and reduced investor profitability. A complex model is built combining long-term investment routines with short-term hourly plant dispatching, following a parametric procedure. The energy mix is composed of wind - PV - tidal power plants and distributed battery storage. Their sizes adapt to the peaking loads, leading to an oversized infrastructure and to low usage rates due to loss of market opportunities during low demand hours. New evaluation criteria are necessary to policy makers in the selection of the energy mix, based on the performance of each plant and storage device, the cost of each power facility and the total system cost. From the investor perspective, the key indicator is the loss of energy generated, therefore storage will support the integration of intermittent renewables by avoiding the power curtailed and accurately sizing the generation mix. The final trade-off is between the reasonable rates of energy in excess to be curtailed, the cost of additional storage and the loss of load probability, which are socially and economically admitted by the regulator and by energy operators, having each conflicting interests and objectives.","PeriodicalId":416860,"journal":{"name":"2019 Offshore Energy and Storage Summit (OSES)","volume":"183 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Building sustainable power mix in small island grids: a multi-criteria analysis\",\"authors\":\"L. Lemiale, R. Loisel, S. Bourguet, A. Roy, M. Machmoun\",\"doi\":\"10.1109/OSES.2019.8867351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Islands have traditionally experienced great dependency on external energy supply and many of them opted for diesel as fuel for power generation. This study tests scenarios of different levels of renewable penetration on the French Atlantic island Ouessant, facing the general problems of the energy planning such as grid reliability, the lack of economies of scale and reduced investor profitability. A complex model is built combining long-term investment routines with short-term hourly plant dispatching, following a parametric procedure. The energy mix is composed of wind - PV - tidal power plants and distributed battery storage. Their sizes adapt to the peaking loads, leading to an oversized infrastructure and to low usage rates due to loss of market opportunities during low demand hours. New evaluation criteria are necessary to policy makers in the selection of the energy mix, based on the performance of each plant and storage device, the cost of each power facility and the total system cost. From the investor perspective, the key indicator is the loss of energy generated, therefore storage will support the integration of intermittent renewables by avoiding the power curtailed and accurately sizing the generation mix. The final trade-off is between the reasonable rates of energy in excess to be curtailed, the cost of additional storage and the loss of load probability, which are socially and economically admitted by the regulator and by energy operators, having each conflicting interests and objectives.\",\"PeriodicalId\":416860,\"journal\":{\"name\":\"2019 Offshore Energy and Storage Summit (OSES)\",\"volume\":\"183 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 Offshore Energy and Storage Summit (OSES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OSES.2019.8867351\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Offshore Energy and Storage Summit (OSES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OSES.2019.8867351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

岛屿传统上非常依赖外部能源供应,其中许多岛屿选择柴油作为发电燃料。本研究测试了法属大西洋岛Ouessant上不同水平的可再生能源渗透情景,面对电网可靠性、缺乏规模经济和投资者盈利能力降低等能源规划的一般问题。根据参数化过程,建立了一个将长期投资程序与短期每小时工厂调度相结合的复杂模型。能源结构由风能-光伏-潮汐能发电厂和分布式电池储能系统组成。它们的大小适应峰值负载,导致超大的基础设施和由于低需求时段市场机会的损失而导致的低使用率。决策者在选择能源组合时需要新的评估标准,该标准应基于每个电厂和存储设备的性能、每个电力设施的成本和系统总成本。从投资者的角度来看,关键指标是产生的能量损失,因此存储将通过避免电力削减和准确调整发电组合来支持间歇性可再生能源的整合。最终的权衡是在合理的过剩能源削减率、额外储存成本和负荷损失概率之间进行,这是监管机构和能源运营商在社会和经济上都承认的,双方的利益和目标相互冲突。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Building sustainable power mix in small island grids: a multi-criteria analysis
Islands have traditionally experienced great dependency on external energy supply and many of them opted for diesel as fuel for power generation. This study tests scenarios of different levels of renewable penetration on the French Atlantic island Ouessant, facing the general problems of the energy planning such as grid reliability, the lack of economies of scale and reduced investor profitability. A complex model is built combining long-term investment routines with short-term hourly plant dispatching, following a parametric procedure. The energy mix is composed of wind - PV - tidal power plants and distributed battery storage. Their sizes adapt to the peaking loads, leading to an oversized infrastructure and to low usage rates due to loss of market opportunities during low demand hours. New evaluation criteria are necessary to policy makers in the selection of the energy mix, based on the performance of each plant and storage device, the cost of each power facility and the total system cost. From the investor perspective, the key indicator is the loss of energy generated, therefore storage will support the integration of intermittent renewables by avoiding the power curtailed and accurately sizing the generation mix. The final trade-off is between the reasonable rates of energy in excess to be curtailed, the cost of additional storage and the loss of load probability, which are socially and economically admitted by the regulator and by energy operators, having each conflicting interests and objectives.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信