用常用的测量方法和CLOSED方案测量视神经鞘。安巴托综合教学医院重症监护室医生的一致性研究

Kerly Apolo Loayza
{"title":"用常用的测量方法和CLOSED方案测量视神经鞘。安巴托综合教学医院重症监护室医生的一致性研究","authors":"Kerly Apolo Loayza","doi":"10.56294/saludcyt2023308","DOIUrl":null,"url":null,"abstract":"Introduction: measuring the diameter of the optic nerve sheath is a widely used procedure for neuromonitoring, since it is a fairly reliable indicator of the state of intracranial pressure.\nObjective: To establish the degree of correlation and concordance between the traditional measurements and with the CLOSED protocol of the diameter of the optic nerve, among the doctors of the Intensive Care Unit of the General Teaching Hospital of Ambato\nMethods: A descriptive, cross-sectional, agreement study was carried out. Fifteen general practitioners residing in the ICU of the General Teaching Hospital of Ambato were included. A healthy volunteer was selected for optic nerve sheath diameter measurement. Measurements were made with the usual technique and, following the CLOSED protocol with ultrasound. Agreement was determined using the Bland-Altman method.\nResults: Traditional method: right sheath (x̄: 0.442; SD: 0.111); left sheath (x̄: 0.486; SD: 0.0995). CLOSED protocol: right sheath (x̄: 0.411; SD: 0.0128); left sheath (x̄: 0.445; SD: 0.00834). Pearson's correlation coefficient: right sheath: r= 0.190 (p= 0.499); left sheath: r= 0.024 (p= 0.932). Concordance coefficient: right sheath (53.3%; 95% CI: 52.3%-54.3%), left sheath (46.7%; 95% CI: 45.7%-47.7%).\nConclusions: There is a weak correlation and moderate agreement between the traditional measurements and with the CLOSED protocol of the diameter of the optic nerve among the doctors of the Intensive Care Unit of the General Teaching Hospital of Ambato. This shows the need to reinforce continuous training activities and the learning curve with these doctors.","PeriodicalId":184806,"journal":{"name":"Salud Ciencia y Tecnología","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of the optic nerve sheath with the usual measurement method and the CLOSED protocol. Concordance study among the doctors of the intensive care unit of the General Teaching Hospital of Ambato\",\"authors\":\"Kerly Apolo Loayza\",\"doi\":\"10.56294/saludcyt2023308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: measuring the diameter of the optic nerve sheath is a widely used procedure for neuromonitoring, since it is a fairly reliable indicator of the state of intracranial pressure.\\nObjective: To establish the degree of correlation and concordance between the traditional measurements and with the CLOSED protocol of the diameter of the optic nerve, among the doctors of the Intensive Care Unit of the General Teaching Hospital of Ambato\\nMethods: A descriptive, cross-sectional, agreement study was carried out. Fifteen general practitioners residing in the ICU of the General Teaching Hospital of Ambato were included. A healthy volunteer was selected for optic nerve sheath diameter measurement. Measurements were made with the usual technique and, following the CLOSED protocol with ultrasound. Agreement was determined using the Bland-Altman method.\\nResults: Traditional method: right sheath (x̄: 0.442; SD: 0.111); left sheath (x̄: 0.486; SD: 0.0995). CLOSED protocol: right sheath (x̄: 0.411; SD: 0.0128); left sheath (x̄: 0.445; SD: 0.00834). Pearson's correlation coefficient: right sheath: r= 0.190 (p= 0.499); left sheath: r= 0.024 (p= 0.932). Concordance coefficient: right sheath (53.3%; 95% CI: 52.3%-54.3%), left sheath (46.7%; 95% CI: 45.7%-47.7%).\\nConclusions: There is a weak correlation and moderate agreement between the traditional measurements and with the CLOSED protocol of the diameter of the optic nerve among the doctors of the Intensive Care Unit of the General Teaching Hospital of Ambato. This shows the need to reinforce continuous training activities and the learning curve with these doctors.\",\"PeriodicalId\":184806,\"journal\":{\"name\":\"Salud Ciencia y Tecnología\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Salud Ciencia y Tecnología\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.56294/saludcyt2023308\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Salud Ciencia y Tecnología","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56294/saludcyt2023308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

简介:测量视神经鞘直径是一种广泛使用的神经监测方法,因为它是颅内压状态的一个相当可靠的指标。目的:探讨安巴塔综合教学医院重症监护病房医生视神经直径的传统测量方法与CLOSED方案的相关性和一致性。方法:采用描述性、横断面、一致性研究。其中包括居住在安巴托综合教学医院重症监护室的15名全科医生。选择一名健康志愿者进行视神经鞘直径测量。测量采用常规技术,并遵循超声封闭协议。使用Bland-Altman方法确定一致性。结果:传统方法:右鞘(x′:0.442;SD: 0.111);左鞘(x′:0.486;SD: 0.0995)。CLOSED协议:右护套(x: 0.411;SD: 0.0128);左护套(x′:0.445;SD: 0.00834)。Pearson相关系数:右鞘:r= 0.190 (p= 0.499);左鞘:r= 0.024 (p= 0.932)。一致性系数:右鞘(53.3%);95% CI: 52.3%-54.3%),左鞘(46.7%;95% ci: 45.7%-47.7%)。结论:安巴托综合教学医院重症监护室的医生对视神经直径的传统测量与CLOSED方案之间存在弱相关性和中度一致性。这表明需要加强对这些医生的持续培训活动和学习曲线。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement of the optic nerve sheath with the usual measurement method and the CLOSED protocol. Concordance study among the doctors of the intensive care unit of the General Teaching Hospital of Ambato
Introduction: measuring the diameter of the optic nerve sheath is a widely used procedure for neuromonitoring, since it is a fairly reliable indicator of the state of intracranial pressure. Objective: To establish the degree of correlation and concordance between the traditional measurements and with the CLOSED protocol of the diameter of the optic nerve, among the doctors of the Intensive Care Unit of the General Teaching Hospital of Ambato Methods: A descriptive, cross-sectional, agreement study was carried out. Fifteen general practitioners residing in the ICU of the General Teaching Hospital of Ambato were included. A healthy volunteer was selected for optic nerve sheath diameter measurement. Measurements were made with the usual technique and, following the CLOSED protocol with ultrasound. Agreement was determined using the Bland-Altman method. Results: Traditional method: right sheath (x̄: 0.442; SD: 0.111); left sheath (x̄: 0.486; SD: 0.0995). CLOSED protocol: right sheath (x̄: 0.411; SD: 0.0128); left sheath (x̄: 0.445; SD: 0.00834). Pearson's correlation coefficient: right sheath: r= 0.190 (p= 0.499); left sheath: r= 0.024 (p= 0.932). Concordance coefficient: right sheath (53.3%; 95% CI: 52.3%-54.3%), left sheath (46.7%; 95% CI: 45.7%-47.7%). Conclusions: There is a weak correlation and moderate agreement between the traditional measurements and with the CLOSED protocol of the diameter of the optic nerve among the doctors of the Intensive Care Unit of the General Teaching Hospital of Ambato. This shows the need to reinforce continuous training activities and the learning curve with these doctors.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信