基于腕关节的光电容积脉搏图对精神压力和心率变异性的评价

Chongyan Chen, Chun-hung Li, Chih-Wei Tsai, Xinghua Deng
{"title":"基于腕关节的光电容积脉搏图对精神压力和心率变异性的评价","authors":"Chongyan Chen, Chun-hung Li, Chih-Wei Tsai, Xinghua Deng","doi":"10.1109/ECBIOS.2019.8807835","DOIUrl":null,"url":null,"abstract":"Heart Rate Variability (HRV) is a significant indicator of physical fitness and mental stresses. Electrocardiography (ECG) is the most common means to detect HRV. However, the nature of the ECG detection limits its convenience and usage time. While wrist-based Photoplethysmography (PPG) provides the possibility of convenient 24/7 HRV monitoring, its accuracy has not been systematically analyzed. We experimented with six healthy subjects and measured PPG from their wrist and ECG from their chest. The result shows that ten HRV parameters have significant differences between stress and non-stress states. Furthermore, the 10-fold accuracy of stress state detection within subjects is 98% and the Leave-One-Participant-Out F1score reaches 80%. The results demonstrate that wrist-based PPG can provide HRV measurements that enable the recognition of mental stress as accurately as ECG, even for a short three-minute temporal window.","PeriodicalId":165579,"journal":{"name":"2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability (ECBIOS)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Evaluation of Mental Stress and Heart Rate Variability Derived from Wrist-Based Photoplethysmography\",\"authors\":\"Chongyan Chen, Chun-hung Li, Chih-Wei Tsai, Xinghua Deng\",\"doi\":\"10.1109/ECBIOS.2019.8807835\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Heart Rate Variability (HRV) is a significant indicator of physical fitness and mental stresses. Electrocardiography (ECG) is the most common means to detect HRV. However, the nature of the ECG detection limits its convenience and usage time. While wrist-based Photoplethysmography (PPG) provides the possibility of convenient 24/7 HRV monitoring, its accuracy has not been systematically analyzed. We experimented with six healthy subjects and measured PPG from their wrist and ECG from their chest. The result shows that ten HRV parameters have significant differences between stress and non-stress states. Furthermore, the 10-fold accuracy of stress state detection within subjects is 98% and the Leave-One-Participant-Out F1score reaches 80%. The results demonstrate that wrist-based PPG can provide HRV measurements that enable the recognition of mental stress as accurately as ECG, even for a short three-minute temporal window.\",\"PeriodicalId\":165579,\"journal\":{\"name\":\"2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability (ECBIOS)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability (ECBIOS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECBIOS.2019.8807835\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability (ECBIOS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECBIOS.2019.8807835","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

心率变异性(HRV)是身体健康和精神压力的重要指标。心电图(ECG)是检测HRV最常用的手段。然而,心电检测的性质限制了它的便捷性和使用时间。虽然基于手腕的光电容积脉搏波(PPG)提供了方便的24/7 HRV监测的可能性,但其准确性尚未得到系统的分析。我们对6名健康受试者进行了实验,并测量了他们手腕上的PPG和胸部的ECG。结果表明,在应力状态和非应力状态下,10个HRV参数存在显著差异。此外,被试内部压力状态检测的10倍正确率为98%,leave - one - participants out f1得分达到80%。结果表明,基于手腕的PPG可以提供HRV测量,能够像ECG一样准确地识别精神压力,即使是短暂的三分钟时间窗口。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Mental Stress and Heart Rate Variability Derived from Wrist-Based Photoplethysmography
Heart Rate Variability (HRV) is a significant indicator of physical fitness and mental stresses. Electrocardiography (ECG) is the most common means to detect HRV. However, the nature of the ECG detection limits its convenience and usage time. While wrist-based Photoplethysmography (PPG) provides the possibility of convenient 24/7 HRV monitoring, its accuracy has not been systematically analyzed. We experimented with six healthy subjects and measured PPG from their wrist and ECG from their chest. The result shows that ten HRV parameters have significant differences between stress and non-stress states. Furthermore, the 10-fold accuracy of stress state detection within subjects is 98% and the Leave-One-Participant-Out F1score reaches 80%. The results demonstrate that wrist-based PPG can provide HRV measurements that enable the recognition of mental stress as accurately as ECG, even for a short three-minute temporal window.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信