{"title":"矩阵变换器驱动双向功率开关损耗分析与评价","authors":"Jun-Koo Kang, H. Hara, E. Yamamoto, E. Watanabe","doi":"10.1109/IAS.2002.1044123","DOIUrl":null,"url":null,"abstract":"The matrix converter (MC) is a bidirectional AC/AC conversion device that generates variable-voltage variable-frequency output from ac voltage utility. Since power topology and switching rules of MC are quite different from voltage source inverter (VSI), power device loss analysis based on VSI topology cannot be applied to MC. In this paper, analysis method for evaluation of bidirectional switch losses of MC is proposed. Variation of collector-emitter voltage and current distribution in bidirectional IGBTs are investigated at various operating conditions for power loss analysis. The validity of the proposed analysis has been verified through the simulations and the experimental results with 7.5 kW MC driven-AC drives system.","PeriodicalId":202482,"journal":{"name":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"43","resultStr":"{\"title\":\"Analysis and evaluation of bi-directional power switch losses for matrix converter drive\",\"authors\":\"Jun-Koo Kang, H. Hara, E. Yamamoto, E. Watanabe\",\"doi\":\"10.1109/IAS.2002.1044123\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The matrix converter (MC) is a bidirectional AC/AC conversion device that generates variable-voltage variable-frequency output from ac voltage utility. Since power topology and switching rules of MC are quite different from voltage source inverter (VSI), power device loss analysis based on VSI topology cannot be applied to MC. In this paper, analysis method for evaluation of bidirectional switch losses of MC is proposed. Variation of collector-emitter voltage and current distribution in bidirectional IGBTs are investigated at various operating conditions for power loss analysis. The validity of the proposed analysis has been verified through the simulations and the experimental results with 7.5 kW MC driven-AC drives system.\",\"PeriodicalId\":202482,\"journal\":{\"name\":\"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"43\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2002.1044123\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2002.1044123","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 43
摘要
矩阵变换器(MC)是一种双向交流/交流转换装置,它从交流电压公用事业产生可变电压变频输出。由于MC的功率拓扑和开关规则与电压源逆变器(VSI)有很大的不同,基于VSI拓扑的功率器件损耗分析无法应用于MC。本文提出了MC双向开关损耗评估的分析方法。研究了双向igbt在不同工作条件下集电极-发射极电压和电流分布的变化规律,用于功率损耗分析。通过7.5 kW MC - ac驱动系统的仿真和实验结果验证了分析的有效性。
Analysis and evaluation of bi-directional power switch losses for matrix converter drive
The matrix converter (MC) is a bidirectional AC/AC conversion device that generates variable-voltage variable-frequency output from ac voltage utility. Since power topology and switching rules of MC are quite different from voltage source inverter (VSI), power device loss analysis based on VSI topology cannot be applied to MC. In this paper, analysis method for evaluation of bidirectional switch losses of MC is proposed. Variation of collector-emitter voltage and current distribution in bidirectional IGBTs are investigated at various operating conditions for power loss analysis. The validity of the proposed analysis has been verified through the simulations and the experimental results with 7.5 kW MC driven-AC drives system.