{"title":"热成像快速无创现场绝缘诊断","authors":"S. Morrison, J. Kluss, J. Ball, Lucas Cagle, Sam Bryan","doi":"10.1109/EIC43217.2019.9046523","DOIUrl":null,"url":null,"abstract":"High voltage electrical failures are dangerous and costly events in any type of power system. The troubleshooting and diagnostic time required to identify and locate these failures can be significant. Partial discharge is one of the early warning signs for electrical degradation. In insulation systems, partial discharge typically occurs in voids located within the dielectric, at material interfaces, or along energized electrode surfaces. Effective methods for finding this failure precursor enabling circumvention of future catastrophic events are highly valuable as successful detection can improve safety, reduce service interruptions, and result in significant financial savings. The presented method was successful in localizing the excess stress without direct line of sight, a clear advantage over night vision and corona cameras. The investigated methodology provides the ability for any user in varying on-site conditions to quickly and noninvasively diagnose the health of a component or device while maintaining safe clearance from energized parts.","PeriodicalId":340602,"journal":{"name":"2019 IEEE Electrical Insulation Conference (EIC)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Thermal Imaging for Rapid Noninvasive On-site Insulation Diagnostics\",\"authors\":\"S. Morrison, J. Kluss, J. Ball, Lucas Cagle, Sam Bryan\",\"doi\":\"10.1109/EIC43217.2019.9046523\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High voltage electrical failures are dangerous and costly events in any type of power system. The troubleshooting and diagnostic time required to identify and locate these failures can be significant. Partial discharge is one of the early warning signs for electrical degradation. In insulation systems, partial discharge typically occurs in voids located within the dielectric, at material interfaces, or along energized electrode surfaces. Effective methods for finding this failure precursor enabling circumvention of future catastrophic events are highly valuable as successful detection can improve safety, reduce service interruptions, and result in significant financial savings. The presented method was successful in localizing the excess stress without direct line of sight, a clear advantage over night vision and corona cameras. The investigated methodology provides the ability for any user in varying on-site conditions to quickly and noninvasively diagnose the health of a component or device while maintaining safe clearance from energized parts.\",\"PeriodicalId\":340602,\"journal\":{\"name\":\"2019 IEEE Electrical Insulation Conference (EIC)\",\"volume\":\"59 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Electrical Insulation Conference (EIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC43217.2019.9046523\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC43217.2019.9046523","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在任何类型的电力系统中,高压电气故障都是危险且代价高昂的事件。识别和定位这些故障所需的故障排除和诊断时间可能非常长。局部放电是电性能退化的早期预警信号之一。在绝缘系统中,局部放电通常发生在介电介质内、材料界面处或带电电极表面的空隙中。发现这种故障前兆并规避未来灾难性事件的有效方法非常有价值,因为成功的检测可以提高安全性,减少服务中断,并节省大量资金。所提出的方法在没有直接瞄准线的情况下成功地定位了多余的应力,这比夜视和日冕相机有明显的优势。所研究的方法为任何用户在不同的现场条件下提供了快速、无创诊断组件或设备健康状况的能力,同时保持与带电部件的安全间隙。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermal Imaging for Rapid Noninvasive On-site Insulation Diagnostics
High voltage electrical failures are dangerous and costly events in any type of power system. The troubleshooting and diagnostic time required to identify and locate these failures can be significant. Partial discharge is one of the early warning signs for electrical degradation. In insulation systems, partial discharge typically occurs in voids located within the dielectric, at material interfaces, or along energized electrode surfaces. Effective methods for finding this failure precursor enabling circumvention of future catastrophic events are highly valuable as successful detection can improve safety, reduce service interruptions, and result in significant financial savings. The presented method was successful in localizing the excess stress without direct line of sight, a clear advantage over night vision and corona cameras. The investigated methodology provides the ability for any user in varying on-site conditions to quickly and noninvasively diagnose the health of a component or device while maintaining safe clearance from energized parts.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信