{"title":"数字角度传感器自校准:提高精度的两种途径","authors":"V. D. Aksenenko, S.I. Matveyev","doi":"10.1109/IMTC.2005.1604175","DOIUrl":null,"url":null,"abstract":"Digital angle sensors built on multipole resolvers and angle-to-digital converters have found a wide application in mission-critical systems operating in severe environment and determine their accuracy and efficiency to a significant extent. A method for self-calibration of digital angle sensors based on integration of two conversion channels with the errors of different spectrums is suggested. Two approaches specially intended to increase the accuracy of self-calibration for the case of high initial errors of the channels are discussed. The results of the simulation and experiment are presented","PeriodicalId":244878,"journal":{"name":"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Digital Angle Sensor Self-Calibration: Two Approaches to Accuracy Increasing\",\"authors\":\"V. D. Aksenenko, S.I. Matveyev\",\"doi\":\"10.1109/IMTC.2005.1604175\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Digital angle sensors built on multipole resolvers and angle-to-digital converters have found a wide application in mission-critical systems operating in severe environment and determine their accuracy and efficiency to a significant extent. A method for self-calibration of digital angle sensors based on integration of two conversion channels with the errors of different spectrums is suggested. Two approaches specially intended to increase the accuracy of self-calibration for the case of high initial errors of the channels are discussed. The results of the simulation and experiment are presented\",\"PeriodicalId\":244878,\"journal\":{\"name\":\"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.2005.1604175\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2005.1604175","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Digital Angle Sensor Self-Calibration: Two Approaches to Accuracy Increasing
Digital angle sensors built on multipole resolvers and angle-to-digital converters have found a wide application in mission-critical systems operating in severe environment and determine their accuracy and efficiency to a significant extent. A method for self-calibration of digital angle sensors based on integration of two conversion channels with the errors of different spectrums is suggested. Two approaches specially intended to increase the accuracy of self-calibration for the case of high initial errors of the channels are discussed. The results of the simulation and experiment are presented