{"title":"基于模糊逻辑的k型热电偶温度测量数字滤波","authors":"H. Korkmaz, B. Can","doi":"10.1109/CIMSA.2003.1227194","DOIUrl":null,"url":null,"abstract":"The performance of a controller designed by using any method depends on the analog quantity to be controlled how accurate and noiseless it is measured. In this paper, the noise on the temperature data measured via a K-type thermocouple mounted on the lab set suitably realized for the purpose of measuring thermal expansion of metal samples is reduced by using two cascade band-pass filters (BPF) whose bandwidth can be set by taking advantage of fuzzy logic controller's relative error membership function.","PeriodicalId":199467,"journal":{"name":"The 3rd International Workshop on Scientific Use of Submarine Cables and Related Technologies, 2003.","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fuzzy logic-based digital filtering for temperature measurement via K-type thermocouple\",\"authors\":\"H. Korkmaz, B. Can\",\"doi\":\"10.1109/CIMSA.2003.1227194\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The performance of a controller designed by using any method depends on the analog quantity to be controlled how accurate and noiseless it is measured. In this paper, the noise on the temperature data measured via a K-type thermocouple mounted on the lab set suitably realized for the purpose of measuring thermal expansion of metal samples is reduced by using two cascade band-pass filters (BPF) whose bandwidth can be set by taking advantage of fuzzy logic controller's relative error membership function.\",\"PeriodicalId\":199467,\"journal\":{\"name\":\"The 3rd International Workshop on Scientific Use of Submarine Cables and Related Technologies, 2003.\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-07-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 3rd International Workshop on Scientific Use of Submarine Cables and Related Technologies, 2003.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIMSA.2003.1227194\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 3rd International Workshop on Scientific Use of Submarine Cables and Related Technologies, 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIMSA.2003.1227194","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fuzzy logic-based digital filtering for temperature measurement via K-type thermocouple
The performance of a controller designed by using any method depends on the analog quantity to be controlled how accurate and noiseless it is measured. In this paper, the noise on the temperature data measured via a K-type thermocouple mounted on the lab set suitably realized for the purpose of measuring thermal expansion of metal samples is reduced by using two cascade band-pass filters (BPF) whose bandwidth can be set by taking advantage of fuzzy logic controller's relative error membership function.