Tao Liu, X. Hao, Xu Yang, Ming Zhao, Qingyun Huang, Lang Huang
{"title":"一种带LCL滤波器的三相并网逆变器重复控制新方案","authors":"Tao Liu, X. Hao, Xu Yang, Ming Zhao, Qingyun Huang, Lang Huang","doi":"10.1109/IPEMC.2012.6258868","DOIUrl":null,"url":null,"abstract":"Grid voltage distortion gives rise to extra grid current harmonics in grid-connected inverter system. To damp these harmonics, this paper proposes a novel control strategy in which inverter output current is regulated by PI controller and grid current is controlled by repetitive controller (RC) for three-phase grid-connected voltage source inverter (VSI) with LCL filter under d-q rotating frame. This paper implements RC to regulate grid current based on the stability of the system under inverter output current control loop. This paper discusses the design of RC and analyzes the stability and effectiveness of the proposed control strategy in damping the grid current harmonics arising from grid voltage distortion. At last, proposed scheme is verified on a 100 kW three-phase grid-connected PV inverter prototype. Simulation and experimental results show that the proposed scheme has a good performance.","PeriodicalId":236136,"journal":{"name":"Proceedings of The 7th International Power Electronics and Motion Control Conference","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"A novel repetitive control scheme for three-phase grid-connected inverter with LCL filter\",\"authors\":\"Tao Liu, X. Hao, Xu Yang, Ming Zhao, Qingyun Huang, Lang Huang\",\"doi\":\"10.1109/IPEMC.2012.6258868\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Grid voltage distortion gives rise to extra grid current harmonics in grid-connected inverter system. To damp these harmonics, this paper proposes a novel control strategy in which inverter output current is regulated by PI controller and grid current is controlled by repetitive controller (RC) for three-phase grid-connected voltage source inverter (VSI) with LCL filter under d-q rotating frame. This paper implements RC to regulate grid current based on the stability of the system under inverter output current control loop. This paper discusses the design of RC and analyzes the stability and effectiveness of the proposed control strategy in damping the grid current harmonics arising from grid voltage distortion. At last, proposed scheme is verified on a 100 kW three-phase grid-connected PV inverter prototype. Simulation and experimental results show that the proposed scheme has a good performance.\",\"PeriodicalId\":236136,\"journal\":{\"name\":\"Proceedings of The 7th International Power Electronics and Motion Control Conference\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of The 7th International Power Electronics and Motion Control Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEMC.2012.6258868\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of The 7th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2012.6258868","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A novel repetitive control scheme for three-phase grid-connected inverter with LCL filter
Grid voltage distortion gives rise to extra grid current harmonics in grid-connected inverter system. To damp these harmonics, this paper proposes a novel control strategy in which inverter output current is regulated by PI controller and grid current is controlled by repetitive controller (RC) for three-phase grid-connected voltage source inverter (VSI) with LCL filter under d-q rotating frame. This paper implements RC to regulate grid current based on the stability of the system under inverter output current control loop. This paper discusses the design of RC and analyzes the stability and effectiveness of the proposed control strategy in damping the grid current harmonics arising from grid voltage distortion. At last, proposed scheme is verified on a 100 kW three-phase grid-connected PV inverter prototype. Simulation and experimental results show that the proposed scheme has a good performance.