多模块神经植入物接地参考的设计考虑

Dorian Haci, Yan Liu, S. Ghoreishizadeh, T. Constandinou
{"title":"多模块神经植入物接地参考的设计考虑","authors":"Dorian Haci, Yan Liu, S. Ghoreishizadeh, T. Constandinou","doi":"10.1109/BIOCAS.2018.8584708","DOIUrl":null,"url":null,"abstract":"Implantable neural interfaces have evolved in the past decades from stimulation-only devices to closed-loop recording and stimulation systems, allowing both for more targeted therapeutic techniques and more advanced prosthetic implants. Emerging applications require multi-module active implantable devices with intrabody power and data transmission. This distributed approach poses a new set of challenges related to inter-module connectivity, functional reliability and patient safety. This paper addresses the ground referencing challenge in active multi-implant systems, with a particular focus on neural recording devices. Three different grounding schemes (passive, drive, and sense) are presented and evaluated in terms of both recording reliability and patient safety. Considerations on the practical implementation of body potential referencing circuitry are finally discussed, with a detailed analysis of their impact on the recording performance.","PeriodicalId":259162,"journal":{"name":"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Design Considerations for Ground Referencing in Multi - Module Neural Implants\",\"authors\":\"Dorian Haci, Yan Liu, S. Ghoreishizadeh, T. Constandinou\",\"doi\":\"10.1109/BIOCAS.2018.8584708\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Implantable neural interfaces have evolved in the past decades from stimulation-only devices to closed-loop recording and stimulation systems, allowing both for more targeted therapeutic techniques and more advanced prosthetic implants. Emerging applications require multi-module active implantable devices with intrabody power and data transmission. This distributed approach poses a new set of challenges related to inter-module connectivity, functional reliability and patient safety. This paper addresses the ground referencing challenge in active multi-implant systems, with a particular focus on neural recording devices. Three different grounding schemes (passive, drive, and sense) are presented and evaluated in terms of both recording reliability and patient safety. Considerations on the practical implementation of body potential referencing circuitry are finally discussed, with a detailed analysis of their impact on the recording performance.\",\"PeriodicalId\":259162,\"journal\":{\"name\":\"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2018.8584708\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2018.8584708","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在过去的几十年里,植入式神经接口已经从仅刺激设备发展到闭环记录和刺激系统,允许更有针对性的治疗技术和更先进的假体植入物。新兴应用需要具有体内电源和数据传输功能的多模块有源植入式设备。这种分布式方法提出了一系列与模块间连接、功能可靠性和患者安全相关的新挑战。本文解决了主动多植入系统中的地面参考挑战,特别关注神经记录设备。提出了三种不同的接地方案(被动、驱动和感应),并在记录可靠性和患者安全性方面进行了评估。最后讨论了实际实现人体电位参考电路的考虑因素,并详细分析了它们对记录性能的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design Considerations for Ground Referencing in Multi - Module Neural Implants
Implantable neural interfaces have evolved in the past decades from stimulation-only devices to closed-loop recording and stimulation systems, allowing both for more targeted therapeutic techniques and more advanced prosthetic implants. Emerging applications require multi-module active implantable devices with intrabody power and data transmission. This distributed approach poses a new set of challenges related to inter-module connectivity, functional reliability and patient safety. This paper addresses the ground referencing challenge in active multi-implant systems, with a particular focus on neural recording devices. Three different grounding schemes (passive, drive, and sense) are presented and evaluated in terms of both recording reliability and patient safety. Considerations on the practical implementation of body potential referencing circuitry are finally discussed, with a detailed analysis of their impact on the recording performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信