{"title":"微囊藻毒素- lr的荧光偏振免疫分析","authors":"O. Hendrickson, E. Zvereva, K. A. Maksimova, A. P. Bondarenko, S. Eremin","doi":"10.47501/978-5-6044060-1-4.31","DOIUrl":null,"url":null,"abstract":"To control the highly toxic phycotoxin microcystin-LR, which comtaminates food, a test sys-tem based on polarizing fluorescent immunoassay has been developed allowing for rapid screening testing, the detection limit of microcystin-LR is up to 7.5 ng / ml; duration of analy-sis – 10 min.","PeriodicalId":302576,"journal":{"name":"Institute of information technology","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"FLUORESCENT POLARIZATION IMMUNOASSAY OF MICROCYSTIN-LR\",\"authors\":\"O. Hendrickson, E. Zvereva, K. A. Maksimova, A. P. Bondarenko, S. Eremin\",\"doi\":\"10.47501/978-5-6044060-1-4.31\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To control the highly toxic phycotoxin microcystin-LR, which comtaminates food, a test sys-tem based on polarizing fluorescent immunoassay has been developed allowing for rapid screening testing, the detection limit of microcystin-LR is up to 7.5 ng / ml; duration of analy-sis – 10 min.\",\"PeriodicalId\":302576,\"journal\":{\"name\":\"Institute of information technology\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Institute of information technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47501/978-5-6044060-1-4.31\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Institute of information technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47501/978-5-6044060-1-4.31","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
为了控制污染食品的高毒性藻毒素微囊藻毒素lr,开发了一种基于偏振荧光免疫法的检测系统,可快速筛选检测,微囊藻毒素lr的检出限可达7.5 ng / ml;分析时间- 10分钟。
FLUORESCENT POLARIZATION IMMUNOASSAY OF MICROCYSTIN-LR
To control the highly toxic phycotoxin microcystin-LR, which comtaminates food, a test sys-tem based on polarizing fluorescent immunoassay has been developed allowing for rapid screening testing, the detection limit of microcystin-LR is up to 7.5 ng / ml; duration of analy-sis – 10 min.