{"title":"测量大电流中断后电流零附近的阳极温度","authors":"A. Schneider","doi":"10.1109/DEIV.2012.6412481","DOIUrl":null,"url":null,"abstract":"The present work is devoted to the estimation of anode temperature immediately after current zero following interruption of high current vacuum arc. Thermal radiation of a hot sample was registered using a 4-channels high-speed camera HSFC. Every camera channel was equipped with an interference filter to record radiation at various wavelengths (600, 700, 775, and 825 nm). First of all, calibrations of camera channels have been made. A molybdenum crucible with known spectral emissivity was used as a calibration sample. Experiments were carried out at different amplitudes of the arc current both with and without the axial magnetic field (AMF).","PeriodicalId":130964,"journal":{"name":"2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Measurements of anode temperature around current zero following interruption of high currents\",\"authors\":\"A. Schneider\",\"doi\":\"10.1109/DEIV.2012.6412481\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present work is devoted to the estimation of anode temperature immediately after current zero following interruption of high current vacuum arc. Thermal radiation of a hot sample was registered using a 4-channels high-speed camera HSFC. Every camera channel was equipped with an interference filter to record radiation at various wavelengths (600, 700, 775, and 825 nm). First of all, calibrations of camera channels have been made. A molybdenum crucible with known spectral emissivity was used as a calibration sample. Experiments were carried out at different amplitudes of the arc current both with and without the axial magnetic field (AMF).\",\"PeriodicalId\":130964,\"journal\":{\"name\":\"2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)\",\"volume\":\"72 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEIV.2012.6412481\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2012.6412481","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文主要研究了大电流真空电弧中断后零电流后立即阳极温度的估计问题。用4通道高速相机HSFC记录热样品的热辐射。每个相机通道都配备了干涉滤光片,以记录不同波长(600、700、775和825 nm)的辐射。首先,对摄像机通道进行了标定。使用已知光谱发射率的钼坩埚作为校准样品。在有轴向磁场和无轴向磁场的情况下,对不同的电弧电流幅值进行了实验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurements of anode temperature around current zero following interruption of high currents
The present work is devoted to the estimation of anode temperature immediately after current zero following interruption of high current vacuum arc. Thermal radiation of a hot sample was registered using a 4-channels high-speed camera HSFC. Every camera channel was equipped with an interference filter to record radiation at various wavelengths (600, 700, 775, and 825 nm). First of all, calibrations of camera channels have been made. A molybdenum crucible with known spectral emissivity was used as a calibration sample. Experiments were carried out at different amplitudes of the arc current both with and without the axial magnetic field (AMF).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信