22.9kV交联聚乙烯电缆劣化特性试验研究依赖于化合物和固化过程

J. Koo, H. Kim, K. Kim, Y. Ann
{"title":"22.9kV交联聚乙烯电缆劣化特性试验研究依赖于化合物和固化过程","authors":"J. Koo, H. Kim, K. Kim, Y. Ann","doi":"10.1109/CEIDP.1993.378876","DOIUrl":null,"url":null,"abstract":"Systematic investigations have been carried out to compare the aging characteristics of 22.9kV XLPE (cross-linked polyethylene) power cables which might be dependent not only on the different types of curing processes on the various antioxidant additives. Sample cables were aged at 60 Hz and 41kV (3Uo), for which hot water at 70/spl deg/C was introduced between the conductor and the semiconductive layer during up to 8760 hrs in a water bath. Afterwards, the AC breakdown characteristics of these aged cables were measured. In a microscopic analysis of the insulating materials, water trees, crystallinity, and oxidation level were measured using a sliced specimen cut into radial sections.<<ETX>>","PeriodicalId":149803,"journal":{"name":"Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An experimental investigation on the degradation characteristics of 22.9kV XLPE cables; dependence on the compounds and curing process\",\"authors\":\"J. Koo, H. Kim, K. Kim, Y. Ann\",\"doi\":\"10.1109/CEIDP.1993.378876\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Systematic investigations have been carried out to compare the aging characteristics of 22.9kV XLPE (cross-linked polyethylene) power cables which might be dependent not only on the different types of curing processes on the various antioxidant additives. Sample cables were aged at 60 Hz and 41kV (3Uo), for which hot water at 70/spl deg/C was introduced between the conductor and the semiconductive layer during up to 8760 hrs in a water bath. Afterwards, the AC breakdown characteristics of these aged cables were measured. In a microscopic analysis of the insulating materials, water trees, crystallinity, and oxidation level were measured using a sliced specimen cut into radial sections.<<ETX>>\",\"PeriodicalId\":149803,\"journal\":{\"name\":\"Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1993.378876\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1993.378876","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对22.9kV交联聚乙烯(XLPE)电力电缆的老化特性进行了系统的比较研究,其老化特性可能不仅取决于不同的固化工艺,还取决于不同的抗氧化添加剂。样品电缆在60 Hz和41kV (3Uo)下老化,在导体和半导体层之间引入70/spl℃的热水,在水浴中长达8760小时。然后,对这些老化电缆的交流击穿特性进行了测量。在绝缘材料的显微分析中,水树、结晶度和氧化水平是用切成径向截面的切片试样来测量的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An experimental investigation on the degradation characteristics of 22.9kV XLPE cables; dependence on the compounds and curing process
Systematic investigations have been carried out to compare the aging characteristics of 22.9kV XLPE (cross-linked polyethylene) power cables which might be dependent not only on the different types of curing processes on the various antioxidant additives. Sample cables were aged at 60 Hz and 41kV (3Uo), for which hot water at 70/spl deg/C was introduced between the conductor and the semiconductive layer during up to 8760 hrs in a water bath. Afterwards, the AC breakdown characteristics of these aged cables were measured. In a microscopic analysis of the insulating materials, water trees, crystallinity, and oxidation level were measured using a sliced specimen cut into radial sections.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信