存在模型误差和状态估计的协调变结构切换攻击

Shan Liu, D. Kundur, T. Zourntos, K. Butler-Purry
{"title":"存在模型误差和状态估计的协调变结构切换攻击","authors":"Shan Liu, D. Kundur, T. Zourntos, K. Butler-Purry","doi":"10.1109/SmartGridComm.2012.6486003","DOIUrl":null,"url":null,"abstract":"Coordinated variable structure switching attacks have been recently proposed as a class of cyber-physical attacks on future smart grid systems. In the traditional formulation of this assault, the opponent is assumed to have a local model of the power system and knowledge of the state (rotor angle and frequency) of a target generator under attack. In this paper, we study the performance of this attack when the opponent has imperfect knowledge of the local system dynamics and partial knowledge of the generator state. In such a situation, we demonstrate how the attacker can make use of Luenberger-based state estimation techniques that are robust to model error to still achieve power system disruption via rotor angle instability.","PeriodicalId":143915,"journal":{"name":"2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Coordinated variable structure switching attack in the presence of model error and state estimation\",\"authors\":\"Shan Liu, D. Kundur, T. Zourntos, K. Butler-Purry\",\"doi\":\"10.1109/SmartGridComm.2012.6486003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Coordinated variable structure switching attacks have been recently proposed as a class of cyber-physical attacks on future smart grid systems. In the traditional formulation of this assault, the opponent is assumed to have a local model of the power system and knowledge of the state (rotor angle and frequency) of a target generator under attack. In this paper, we study the performance of this attack when the opponent has imperfect knowledge of the local system dynamics and partial knowledge of the generator state. In such a situation, we demonstrate how the attacker can make use of Luenberger-based state estimation techniques that are robust to model error to still achieve power system disruption via rotor angle instability.\",\"PeriodicalId\":143915,\"journal\":{\"name\":\"2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SmartGridComm.2012.6486003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SmartGridComm.2012.6486003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

协调变结构切换攻击最近被提出作为未来智能电网系统的一类网络物理攻击。在这种攻击的传统公式中,假设对手有电力系统的局部模型,并且知道被攻击目标发电机的状态(转子角度和频率)。在本文中,我们研究了当对手不完全了解局部系统动态和部分了解发电机状态时,这种攻击的性能。在这种情况下,我们演示了攻击者如何利用基于luenberger的状态估计技术,该技术对模型误差具有鲁棒性,仍然可以通过转子角度不稳定实现电力系统中断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Coordinated variable structure switching attack in the presence of model error and state estimation
Coordinated variable structure switching attacks have been recently proposed as a class of cyber-physical attacks on future smart grid systems. In the traditional formulation of this assault, the opponent is assumed to have a local model of the power system and knowledge of the state (rotor angle and frequency) of a target generator under attack. In this paper, we study the performance of this attack when the opponent has imperfect knowledge of the local system dynamics and partial knowledge of the generator state. In such a situation, we demonstrate how the attacker can make use of Luenberger-based state estimation techniques that are robust to model error to still achieve power system disruption via rotor angle instability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信