历史砖石塔结构健康监测

C. Gentile, Marco Guidobaldi, A. Saisi
{"title":"历史砖石塔结构健康监测","authors":"C. Gentile, Marco Guidobaldi, A. Saisi","doi":"10.1109/EESMS.2015.7175872","DOIUrl":null,"url":null,"abstract":"The paper summarizes the results of the first 15 months of continuous dynamic monitoring of the Gabbia tower in Mantua. After the Italian seismic events of May 2012 a wide investigation program was performed on the tower, suggesting the installation of a dynamic monitoring system in the upper region of the building. The continuously recorded signals allowed the automated identification of the natural frequencies of the key vibration modes of the structure and the clear detection of the effects of temperature on the natural frequencies. The study of the correlation between frequencies and temperature also revealed the non-reversible structural effects determined by a far-field earthquake, proving the effectiveness of damage detection techniques based on frequency shifts.","PeriodicalId":346259,"journal":{"name":"2015 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS) Proceedings","volume":"84 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Structural health monitoring of a historic masonry tower\",\"authors\":\"C. Gentile, Marco Guidobaldi, A. Saisi\",\"doi\":\"10.1109/EESMS.2015.7175872\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper summarizes the results of the first 15 months of continuous dynamic monitoring of the Gabbia tower in Mantua. After the Italian seismic events of May 2012 a wide investigation program was performed on the tower, suggesting the installation of a dynamic monitoring system in the upper region of the building. The continuously recorded signals allowed the automated identification of the natural frequencies of the key vibration modes of the structure and the clear detection of the effects of temperature on the natural frequencies. The study of the correlation between frequencies and temperature also revealed the non-reversible structural effects determined by a far-field earthquake, proving the effectiveness of damage detection techniques based on frequency shifts.\",\"PeriodicalId\":346259,\"journal\":{\"name\":\"2015 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS) Proceedings\",\"volume\":\"84 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS) Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EESMS.2015.7175872\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Workshop on Environmental, Energy, and Structural Monitoring Systems (EESMS) Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EESMS.2015.7175872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文总结了曼图亚加比亚塔前15个月连续动态监测的结果。2012年5月意大利地震事件发生后,对塔楼进行了广泛的调查,建议在建筑的上部区域安装动态监测系统。连续记录的信号允许自动识别结构的关键振动模式的固有频率,并清楚地检测温度对固有频率的影响。频率与温度之间的相关性研究还揭示了远场地震所确定的不可逆结构效应,证明了基于频移的损伤检测技术的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Structural health monitoring of a historic masonry tower
The paper summarizes the results of the first 15 months of continuous dynamic monitoring of the Gabbia tower in Mantua. After the Italian seismic events of May 2012 a wide investigation program was performed on the tower, suggesting the installation of a dynamic monitoring system in the upper region of the building. The continuously recorded signals allowed the automated identification of the natural frequencies of the key vibration modes of the structure and the clear detection of the effects of temperature on the natural frequencies. The study of the correlation between frequencies and temperature also revealed the non-reversible structural effects determined by a far-field earthquake, proving the effectiveness of damage detection techniques based on frequency shifts.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信