双小体机械心脏瓣膜关闭声的体外表征

A. Bagno, R. Buselli, F. Anzil, V. Tarzia, V. Pengo, A. Ruggeri, T. Bottio, G. Gerosa
{"title":"双小体机械心脏瓣膜关闭声的体外表征","authors":"A. Bagno, R. Buselli, F. Anzil, V. Tarzia, V. Pengo, A. Ruggeri, T. Bottio, G. Gerosa","doi":"10.1109/CIC.2008.4749199","DOIUrl":null,"url":null,"abstract":"Due to the asynchronous closure of the leaflets , the closing sound of a bileaflet Mechanical Hearth Valve (MHV) is characterised by the presence of two peaks in the time domain. The closing sounds of four commercial MHVs have been acquired in vitro using the Sheffield Pulse Duplicator, under different working conditions to simulate as many physiological ones. The MHVs closing sounds were detected by a commercial apparatus (Myotis 3c, Cardiosignal GmbH). Closing sound spectra (10-22 kHz) have been statistically analysed and compared. A preliminary classification of the tested MHVs is herewith presented; differences in their phonographic behaviour are briefly discussed. This work would allow moving towards the early phonocardiographic diagnosis of bileaflet MHVs malfunction due to endothelial pannus deposition and/or thrombosis.","PeriodicalId":194782,"journal":{"name":"2008 Computers in Cardiology","volume":"75 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"In vitro characterization of bileaflet Mechanical Heart Valves closing sound\",\"authors\":\"A. Bagno, R. Buselli, F. Anzil, V. Tarzia, V. Pengo, A. Ruggeri, T. Bottio, G. Gerosa\",\"doi\":\"10.1109/CIC.2008.4749199\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to the asynchronous closure of the leaflets , the closing sound of a bileaflet Mechanical Hearth Valve (MHV) is characterised by the presence of two peaks in the time domain. The closing sounds of four commercial MHVs have been acquired in vitro using the Sheffield Pulse Duplicator, under different working conditions to simulate as many physiological ones. The MHVs closing sounds were detected by a commercial apparatus (Myotis 3c, Cardiosignal GmbH). Closing sound spectra (10-22 kHz) have been statistically analysed and compared. A preliminary classification of the tested MHVs is herewith presented; differences in their phonographic behaviour are briefly discussed. This work would allow moving towards the early phonocardiographic diagnosis of bileaflet MHVs malfunction due to endothelial pannus deposition and/or thrombosis.\",\"PeriodicalId\":194782,\"journal\":{\"name\":\"2008 Computers in Cardiology\",\"volume\":\"75 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Computers in Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2008.4749199\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Computers in Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2008.4749199","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

由于单叶的异步关闭,双叶机械炉底阀(MHV)的关闭声音的特征是在时域中存在两个峰。利用谢菲尔德脉冲复制器在不同的工作条件下模拟了四种商业mhv的关闭声音,以模拟尽可能多的生理声音。商用仪器(Myotis 3c, Cardiosignal GmbH)检测mhv闭合音。对闭合声谱(10- 22khz)进行了统计分析和比较。现就已测试的mhv作初步分类;简要讨论了它们在留声机行为上的差异。这项工作将有助于对由于内皮膜沉积和/或血栓形成而导致的双小叶mhv功能障碍进行早期心音诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In vitro characterization of bileaflet Mechanical Heart Valves closing sound
Due to the asynchronous closure of the leaflets , the closing sound of a bileaflet Mechanical Hearth Valve (MHV) is characterised by the presence of two peaks in the time domain. The closing sounds of four commercial MHVs have been acquired in vitro using the Sheffield Pulse Duplicator, under different working conditions to simulate as many physiological ones. The MHVs closing sounds were detected by a commercial apparatus (Myotis 3c, Cardiosignal GmbH). Closing sound spectra (10-22 kHz) have been statistically analysed and compared. A preliminary classification of the tested MHVs is herewith presented; differences in their phonographic behaviour are briefly discussed. This work would allow moving towards the early phonocardiographic diagnosis of bileaflet MHVs malfunction due to endothelial pannus deposition and/or thrombosis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信