基于延迟LMS的PV-DSTATCOM系统自适应控制

Ikhlaq Hussain, R. Agarwal, Bhim Singh
{"title":"基于延迟LMS的PV-DSTATCOM系统自适应控制","authors":"Ikhlaq Hussain, R. Agarwal, Bhim Singh","doi":"10.1109/ICEPE50861.2021.9404442","DOIUrl":null,"url":null,"abstract":"The dual-mode single-stage PV-DSTATCOM (Photovoltaic-Distributed Static Compensator) system tied to the AC grid is presented using a DLMS (Delayed Least Mean Square) based adaptive control technique. The proposed multifunctional PV-DSTATCOM system works under two main modes of operation: 1) DSTATCOM and 2) PV-DSTATCOM mode. In mode-1, when there is no PV power generation, it acts as a DSTATCOM for mitigating various power quality issues at Point of Common Coupling due to high Total Harmonic Distortion of load currents. In mode-2, it acts as a PV-DSTATCOM and transfers power to the AC grid and loads. For implementing the dual modes of operation, an intelligent DLMS based adaptive control algorithm is implemented on a developed laboratory prototype to carry out several experimental tests under varying conditions.","PeriodicalId":250203,"journal":{"name":"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Delayed LMS Based Adaptive Control of PV-DSTATCOM System\",\"authors\":\"Ikhlaq Hussain, R. Agarwal, Bhim Singh\",\"doi\":\"10.1109/ICEPE50861.2021.9404442\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The dual-mode single-stage PV-DSTATCOM (Photovoltaic-Distributed Static Compensator) system tied to the AC grid is presented using a DLMS (Delayed Least Mean Square) based adaptive control technique. The proposed multifunctional PV-DSTATCOM system works under two main modes of operation: 1) DSTATCOM and 2) PV-DSTATCOM mode. In mode-1, when there is no PV power generation, it acts as a DSTATCOM for mitigating various power quality issues at Point of Common Coupling due to high Total Harmonic Distortion of load currents. In mode-2, it acts as a PV-DSTATCOM and transfers power to the AC grid and loads. For implementing the dual modes of operation, an intelligent DLMS based adaptive control algorithm is implemented on a developed laboratory prototype to carry out several experimental tests under varying conditions.\",\"PeriodicalId\":250203,\"journal\":{\"name\":\"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEPE50861.2021.9404442\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE50861.2021.9404442","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

采用基于延迟最小均方(DLMS)的自适应控制技术,提出了与交流电网相连接的双模单级PV-DSTATCOM(光伏分布式静态补偿器)系统。本文提出的多功能PV-DSTATCOM系统工作在两种主要的工作模式下:1)DSTATCOM和2)PV-DSTATCOM模式。在模式1中,当没有光伏发电时,它作为DSTATCOM,缓解因负载电流总谐波畸变高而导致的公共耦合点的各种电能质量问题。在模式2中,它充当PV-DSTATCOM并将电力传输到交流电网和负载。为了实现双工作模式,在研制的实验室样机上实现了一种基于智能DLMS的自适应控制算法,并在不同条件下进行了多次实验测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Delayed LMS Based Adaptive Control of PV-DSTATCOM System
The dual-mode single-stage PV-DSTATCOM (Photovoltaic-Distributed Static Compensator) system tied to the AC grid is presented using a DLMS (Delayed Least Mean Square) based adaptive control technique. The proposed multifunctional PV-DSTATCOM system works under two main modes of operation: 1) DSTATCOM and 2) PV-DSTATCOM mode. In mode-1, when there is no PV power generation, it acts as a DSTATCOM for mitigating various power quality issues at Point of Common Coupling due to high Total Harmonic Distortion of load currents. In mode-2, it acts as a PV-DSTATCOM and transfers power to the AC grid and loads. For implementing the dual modes of operation, an intelligent DLMS based adaptive control algorithm is implemented on a developed laboratory prototype to carry out several experimental tests under varying conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信