开发新的特维宁阻抗测定技术和在线应用的电压稳定性评价指标

Ahadu Hilawie, F. Shewarega
{"title":"开发新的特维宁阻抗测定技术和在线应用的电压稳定性评价指标","authors":"Ahadu Hilawie, F. Shewarega","doi":"10.1109/PowerAfrica52236.2021.9543381","DOIUrl":null,"url":null,"abstract":"In Thevenin impedance determination techniques, which are used for voltage stability assessment, approximations are common. The approximations produce erroneous results during critical operating times. This paper has solved the approximation problems and comes up with new Thevenin impedance determination technique suitable for online voltage stability assessment. The Technique is tested on a simple three bus test system, and produced results that match with the actual values. Using this new Thevenin impedance determination Technique, a new voltage stability index is also developed. The index is tested on IEEE 14 bus system and it has, effectively, identified weakest and strongest buses. The test is also compared with the result from other methods, and its effectiveness for online voltage stability assessment is shown.","PeriodicalId":370999,"journal":{"name":"2021 IEEE PES/IAS PowerAfrica","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Developing New Thevenin Impedance Determination Technique and Voltage Stability Assessment Index for Online Application\",\"authors\":\"Ahadu Hilawie, F. Shewarega\",\"doi\":\"10.1109/PowerAfrica52236.2021.9543381\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In Thevenin impedance determination techniques, which are used for voltage stability assessment, approximations are common. The approximations produce erroneous results during critical operating times. This paper has solved the approximation problems and comes up with new Thevenin impedance determination technique suitable for online voltage stability assessment. The Technique is tested on a simple three bus test system, and produced results that match with the actual values. Using this new Thevenin impedance determination Technique, a new voltage stability index is also developed. The index is tested on IEEE 14 bus system and it has, effectively, identified weakest and strongest buses. The test is also compared with the result from other methods, and its effectiveness for online voltage stability assessment is shown.\",\"PeriodicalId\":370999,\"journal\":{\"name\":\"2021 IEEE PES/IAS PowerAfrica\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE PES/IAS PowerAfrica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PowerAfrica52236.2021.9543381\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE PES/IAS PowerAfrica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PowerAfrica52236.2021.9543381","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在用于电压稳定性评估的Thevenin阻抗测定技术中,近似是常见的。在关键的操作时间内,近似会产生错误的结果。本文解决了近似问题,提出了一种适用于在线电压稳定性评估的戴文宁阻抗测定新方法。该技术在一个简单的三总线测试系统上进行了测试,结果与实际值吻合。利用这种新的特文宁阻抗测定技术,还提出了一种新的电压稳定性指标。该指标在IEEE 14总线系统上进行了测试,有效地识别出了最弱和最强总线。并与其他方法的测试结果进行了比较,验证了该方法对在线电压稳定性评估的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Developing New Thevenin Impedance Determination Technique and Voltage Stability Assessment Index for Online Application
In Thevenin impedance determination techniques, which are used for voltage stability assessment, approximations are common. The approximations produce erroneous results during critical operating times. This paper has solved the approximation problems and comes up with new Thevenin impedance determination technique suitable for online voltage stability assessment. The Technique is tested on a simple three bus test system, and produced results that match with the actual values. Using this new Thevenin impedance determination Technique, a new voltage stability index is also developed. The index is tested on IEEE 14 bus system and it has, effectively, identified weakest and strongest buses. The test is also compared with the result from other methods, and its effectiveness for online voltage stability assessment is shown.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信