{"title":"T-Scan III系统的精度和可靠性","authors":"Bernd Koos, DMD","doi":"10.4018/978-1-5225-9254-9.ch003","DOIUrl":null,"url":null,"abstract":"Precise analysis of occlusal contacts and occlusal force is a problem in functional diagnostics that has not yet been satisfactorily resolved, despite the fact that the deleterious consequences of an unbalanced occlusion are widespread, and can be severe. In clinical practice, the present-day analysis of the occlusion is reduced to depicting force with color-marking foils that leave ink marks upon the teeth. However, these foils only indicate the localization of contacts, but do not describe reliably the occlusal force relationships. Precise analysis that incorporates time resolution, and plots the distribution of forces within the occlusion, is not possible when employing the traditional occlusal indicator methods. A detailed occlusal force and timing analysis can only be provided by performing a computer-assisted analysis, using the T-Scan III system (Tekscan, Inc. S. Boston, MA, USA), which records changing relative occlusal force levels and real-time occlusal contact sequence data, with high definition (HD) recording sensors. The following chapter demonstrates the accuracy and reliability of this computer-based occlusal measurement method that reliably describes the time-dependent distribution of occlusal force evolution.","PeriodicalId":225442,"journal":{"name":"Advances in Medical Technologies and Clinical Practice","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Precision and Reliability of the T-Scan III System\",\"authors\":\"Bernd Koos, DMD\",\"doi\":\"10.4018/978-1-5225-9254-9.ch003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Precise analysis of occlusal contacts and occlusal force is a problem in functional diagnostics that has not yet been satisfactorily resolved, despite the fact that the deleterious consequences of an unbalanced occlusion are widespread, and can be severe. In clinical practice, the present-day analysis of the occlusion is reduced to depicting force with color-marking foils that leave ink marks upon the teeth. However, these foils only indicate the localization of contacts, but do not describe reliably the occlusal force relationships. Precise analysis that incorporates time resolution, and plots the distribution of forces within the occlusion, is not possible when employing the traditional occlusal indicator methods. A detailed occlusal force and timing analysis can only be provided by performing a computer-assisted analysis, using the T-Scan III system (Tekscan, Inc. S. Boston, MA, USA), which records changing relative occlusal force levels and real-time occlusal contact sequence data, with high definition (HD) recording sensors. The following chapter demonstrates the accuracy and reliability of this computer-based occlusal measurement method that reliably describes the time-dependent distribution of occlusal force evolution.\",\"PeriodicalId\":225442,\"journal\":{\"name\":\"Advances in Medical Technologies and Clinical Practice\",\"volume\":\"54 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Medical Technologies and Clinical Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4018/978-1-5225-9254-9.ch003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Medical Technologies and Clinical Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4018/978-1-5225-9254-9.ch003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

咬合接触和咬合力的精确分析是功能诊断中的一个尚未得到满意解决的问题,尽管咬合不平衡的有害后果是广泛的,并且可能是严重的。在临床实践中,目前对咬合的分析被简化为用在牙齿上留下墨迹的彩色标记箔来描绘力。然而,这些箔片仅表明接触的定位,但不能可靠地描述咬合力关系。当采用传统的咬合指示方法时,不可能进行精确的分析,包括时间分辨率,并绘制咬合内的力分布。详细的咬合力和时间分析只能通过使用T-Scan III系统(Tekscan, Inc.)进行计算机辅助分析来提供。S. Boston, MA, USA),使用高清(HD)记录传感器记录变化的相对咬合力水平和实时咬合接触序列数据。下一章演示了这种基于计算机的咬合测量方法的准确性和可靠性,该方法可靠地描述了咬合力演变的随时间分布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Precision and Reliability of the T-Scan III System
Precise analysis of occlusal contacts and occlusal force is a problem in functional diagnostics that has not yet been satisfactorily resolved, despite the fact that the deleterious consequences of an unbalanced occlusion are widespread, and can be severe. In clinical practice, the present-day analysis of the occlusion is reduced to depicting force with color-marking foils that leave ink marks upon the teeth. However, these foils only indicate the localization of contacts, but do not describe reliably the occlusal force relationships. Precise analysis that incorporates time resolution, and plots the distribution of forces within the occlusion, is not possible when employing the traditional occlusal indicator methods. A detailed occlusal force and timing analysis can only be provided by performing a computer-assisted analysis, using the T-Scan III system (Tekscan, Inc. S. Boston, MA, USA), which records changing relative occlusal force levels and real-time occlusal contact sequence data, with high definition (HD) recording sensors. The following chapter demonstrates the accuracy and reliability of this computer-based occlusal measurement method that reliably describes the time-dependent distribution of occlusal force evolution.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信