M. Abd-El-Aziz, M. Nashed, A. Adly, E. Abou-El-Zahab
{"title":"与整流负载并联的三相母线的电磁力密度","authors":"M. Abd-El-Aziz, M. Nashed, A. Adly, E. Abou-El-Zahab","doi":"10.1109/APAP.2011.6180367","DOIUrl":null,"url":null,"abstract":"This paper introduces an analytical approach to compute local force density in every busbar section and the overall forces per unit length for every busbar. An assessment of the overall forces on various busbar structures is made considering all the factors affecting these forces. These factors are the busbars dimension, the instantaneous current values that determine the busbar carrying the maximum current value, inter-busbar spacing, the vicinity of metal conducting plate and the busbar arrangements, either the cross sectional area, in which the current density flow perpendicular to the surface, is horizontal or vertical arrangement but in all cases it is laid horizontally. The local force density and overall force computation is made in case of steady state current neglecting harmonics, steady state current considering harmonics and in case of short circuit current. An experimental model of nonlinear load is implemented to investigate the local force density in the presence of harmonic currents over one cycle.","PeriodicalId":435652,"journal":{"name":"2011 International Conference on Advanced Power System Automation and Protection","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Electromagnetic forces densities for 3 phase busbar parallel connected to rectifier load\",\"authors\":\"M. Abd-El-Aziz, M. Nashed, A. Adly, E. Abou-El-Zahab\",\"doi\":\"10.1109/APAP.2011.6180367\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces an analytical approach to compute local force density in every busbar section and the overall forces per unit length for every busbar. An assessment of the overall forces on various busbar structures is made considering all the factors affecting these forces. These factors are the busbars dimension, the instantaneous current values that determine the busbar carrying the maximum current value, inter-busbar spacing, the vicinity of metal conducting plate and the busbar arrangements, either the cross sectional area, in which the current density flow perpendicular to the surface, is horizontal or vertical arrangement but in all cases it is laid horizontally. The local force density and overall force computation is made in case of steady state current neglecting harmonics, steady state current considering harmonics and in case of short circuit current. An experimental model of nonlinear load is implemented to investigate the local force density in the presence of harmonic currents over one cycle.\",\"PeriodicalId\":435652,\"journal\":{\"name\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"volume\":\"66 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Advanced Power System Automation and Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APAP.2011.6180367\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Advanced Power System Automation and Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APAP.2011.6180367","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Electromagnetic forces densities for 3 phase busbar parallel connected to rectifier load
This paper introduces an analytical approach to compute local force density in every busbar section and the overall forces per unit length for every busbar. An assessment of the overall forces on various busbar structures is made considering all the factors affecting these forces. These factors are the busbars dimension, the instantaneous current values that determine the busbar carrying the maximum current value, inter-busbar spacing, the vicinity of metal conducting plate and the busbar arrangements, either the cross sectional area, in which the current density flow perpendicular to the surface, is horizontal or vertical arrangement but in all cases it is laid horizontally. The local force density and overall force computation is made in case of steady state current neglecting harmonics, steady state current considering harmonics and in case of short circuit current. An experimental model of nonlinear load is implemented to investigate the local force density in the presence of harmonic currents over one cycle.