{"title":"由模糊规则和时间估计器控制的巴勒斯坦一家医院的独立清洁电力供应","authors":"M. Mushtaha, G. Krost","doi":"10.1109/ISAP.2011.6082164","DOIUrl":null,"url":null,"abstract":"Stand alone wind-Diesel power systems can be an attractive solution for the supply of remotely located consumers or the provision of enhanced energy independence particularly in the Near-East region. This paper presents a dynamic behavior of a hybrid power system containing a wind turbine induction generator and a Diesel generator set supplying electrical demands for the main hospital in Gaza-Strip - Palestine. In this regard, hydrogen path and accumulator bank are added as long term and short term storage devices - respectively - in order to balance power in the system. In this paper, a proper fuzzy logic algorithm followed by a time estimator is applied to intelligently manage the energy storage strategy depending on the battery-bank state of charge, the hydrogen tank pressure, the prospective wind speed and the excess power under a given load profile of the hospital. The simulation results have been obtained in Matlab-Simulink environment, using SimPowerSystems and Fuzzy Logic toolboxes.","PeriodicalId":424662,"journal":{"name":"2011 16th International Conference on Intelligent System Applications to Power Systems","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Independent and clean electricity supply for a hospital in palestine controlled by fuzzy rules and time estimator\",\"authors\":\"M. Mushtaha, G. Krost\",\"doi\":\"10.1109/ISAP.2011.6082164\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Stand alone wind-Diesel power systems can be an attractive solution for the supply of remotely located consumers or the provision of enhanced energy independence particularly in the Near-East region. This paper presents a dynamic behavior of a hybrid power system containing a wind turbine induction generator and a Diesel generator set supplying electrical demands for the main hospital in Gaza-Strip - Palestine. In this regard, hydrogen path and accumulator bank are added as long term and short term storage devices - respectively - in order to balance power in the system. In this paper, a proper fuzzy logic algorithm followed by a time estimator is applied to intelligently manage the energy storage strategy depending on the battery-bank state of charge, the hydrogen tank pressure, the prospective wind speed and the excess power under a given load profile of the hospital. The simulation results have been obtained in Matlab-Simulink environment, using SimPowerSystems and Fuzzy Logic toolboxes.\",\"PeriodicalId\":424662,\"journal\":{\"name\":\"2011 16th International Conference on Intelligent System Applications to Power Systems\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 16th International Conference on Intelligent System Applications to Power Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISAP.2011.6082164\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 16th International Conference on Intelligent System Applications to Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAP.2011.6082164","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Independent and clean electricity supply for a hospital in palestine controlled by fuzzy rules and time estimator
Stand alone wind-Diesel power systems can be an attractive solution for the supply of remotely located consumers or the provision of enhanced energy independence particularly in the Near-East region. This paper presents a dynamic behavior of a hybrid power system containing a wind turbine induction generator and a Diesel generator set supplying electrical demands for the main hospital in Gaza-Strip - Palestine. In this regard, hydrogen path and accumulator bank are added as long term and short term storage devices - respectively - in order to balance power in the system. In this paper, a proper fuzzy logic algorithm followed by a time estimator is applied to intelligently manage the energy storage strategy depending on the battery-bank state of charge, the hydrogen tank pressure, the prospective wind speed and the excess power under a given load profile of the hospital. The simulation results have been obtained in Matlab-Simulink environment, using SimPowerSystems and Fuzzy Logic toolboxes.