分析蒸汽厂OCCWP泵损坏2×115兆瓦

T. Sianturi, Sindak Hutauruk, Fiktor Sihombing
{"title":"分析蒸汽厂OCCWP泵损坏2×115兆瓦","authors":"T. Sianturi, Sindak Hutauruk, Fiktor Sihombing","doi":"10.36655/sprocket.v3i1.572","DOIUrl":null,"url":null,"abstract":"The use of pumps in the industrial world, especially in power plants, cannot be separated from problems that arise that can cause losses. The research was conducted at PLTU 2 X 115 MW by taking a case that had happened to the pump, namely the Open Cycle Cooling Water Pump 2A. The analytical method used in this final project is the vibration analysis method, namely by reading the spectrum of the data retrieval results so that it can be seen what happens to the equipment that experiences an increase in vibration. \n Bearing damage can be seen in the spectrum image of the measurement results, where the appearance of the spectrum in the high frequency range is an indication of bearing damage. And the high vibration which reaches 13.06 mm/s and is already in the danger category based on ISO 10816-3.","PeriodicalId":156199,"journal":{"name":"SPROCKET JOURNAL OF MECHANICAL ENGINEERING","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analisa Kerusakan Pompa OCCWP Pada Pembangkit Listrik Tenaga Uap 2 x 115 MW\",\"authors\":\"T. Sianturi, Sindak Hutauruk, Fiktor Sihombing\",\"doi\":\"10.36655/sprocket.v3i1.572\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The use of pumps in the industrial world, especially in power plants, cannot be separated from problems that arise that can cause losses. The research was conducted at PLTU 2 X 115 MW by taking a case that had happened to the pump, namely the Open Cycle Cooling Water Pump 2A. The analytical method used in this final project is the vibration analysis method, namely by reading the spectrum of the data retrieval results so that it can be seen what happens to the equipment that experiences an increase in vibration. \\n Bearing damage can be seen in the spectrum image of the measurement results, where the appearance of the spectrum in the high frequency range is an indication of bearing damage. And the high vibration which reaches 13.06 mm/s and is already in the danger category based on ISO 10816-3.\",\"PeriodicalId\":156199,\"journal\":{\"name\":\"SPROCKET JOURNAL OF MECHANICAL ENGINEERING\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SPROCKET JOURNAL OF MECHANICAL ENGINEERING\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36655/sprocket.v3i1.572\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SPROCKET JOURNAL OF MECHANICAL ENGINEERING","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36655/sprocket.v3i1.572","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在工业领域,特别是在发电厂,水泵的使用离不开可能造成损失的问题。该研究是在PLTU 2 X 115 MW上进行的,采用了一个发生在泵上的案例,即2A开式循环冷却水泵。在这个final project中使用的分析方法是振动分析方法,即通过读取数据检索结果的频谱,从而可以看到振动增加的设备发生了什么。在测量结果的频谱图像中可以看到轴承损坏,其中高频范围内频谱的出现是轴承损坏的指示。高振动达到13.06毫米/秒,根据ISO 10816-3已经处于危险类别。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analisa Kerusakan Pompa OCCWP Pada Pembangkit Listrik Tenaga Uap 2 x 115 MW
The use of pumps in the industrial world, especially in power plants, cannot be separated from problems that arise that can cause losses. The research was conducted at PLTU 2 X 115 MW by taking a case that had happened to the pump, namely the Open Cycle Cooling Water Pump 2A. The analytical method used in this final project is the vibration analysis method, namely by reading the spectrum of the data retrieval results so that it can be seen what happens to the equipment that experiences an increase in vibration.  Bearing damage can be seen in the spectrum image of the measurement results, where the appearance of the spectrum in the high frequency range is an indication of bearing damage. And the high vibration which reaches 13.06 mm/s and is already in the danger category based on ISO 10816-3.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信