家用空调机组的电源管理

Zinah J. Ahmed, Ali A. M. Al-Khafaji
{"title":"家用空调机组的电源管理","authors":"Zinah J. Ahmed, Ali A. M. Al-Khafaji","doi":"10.1109/DeSE.2018.00020","DOIUrl":null,"url":null,"abstract":"Domestic air conditioner equipment run long time a day to create a comfortable environment during hot summer weather. Instead of this, using such units may involve lots of risks. Air condition unit is one of the high electric power consumption appliances. This power surges each time the refrigerant compressor starts up leads to increase the temperature of electric connections. Coupled with the extreme hot weather put the resident's lives and their properties in real danger. A well-known heating-cooling cycle of the electric connections due to increasing-decreasing electric current cycle passing through the connections as a result of inrush current each time the compressor starting up leads to weak them. With the time, these connections become hotter and hotter to a specific temperature at which fire may ignite and/ or poisoning gases may emit from sockets and joints. Manufacturers start using inrush current limiters in the power circuit and an active bypass circuit that is activated after the inrush current peak decays. This paper presents an investigation of a simple method to manage the inrush current during the compressor starting up each start-stop cycle. This procedure includes switch OFF the unit's fan just before the compressor starting up to provide an extra power to minimising the unit total inrush current. While the fan is continue rotating by its inertia and when the compressor reaches its steady state current or just before it, the fan is reconnected. Inrush current of the fan in this case will significantly reduce because it is continue rotating. High inrush current is needed to start any electrical motor from its idle to rotating state at its steady state speed.","PeriodicalId":404735,"journal":{"name":"2018 11th International Conference on Developments in eSystems Engineering (DeSE)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Power Management of Domestic Air Condition Units\",\"authors\":\"Zinah J. Ahmed, Ali A. M. Al-Khafaji\",\"doi\":\"10.1109/DeSE.2018.00020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Domestic air conditioner equipment run long time a day to create a comfortable environment during hot summer weather. Instead of this, using such units may involve lots of risks. Air condition unit is one of the high electric power consumption appliances. This power surges each time the refrigerant compressor starts up leads to increase the temperature of electric connections. Coupled with the extreme hot weather put the resident's lives and their properties in real danger. A well-known heating-cooling cycle of the electric connections due to increasing-decreasing electric current cycle passing through the connections as a result of inrush current each time the compressor starting up leads to weak them. With the time, these connections become hotter and hotter to a specific temperature at which fire may ignite and/ or poisoning gases may emit from sockets and joints. Manufacturers start using inrush current limiters in the power circuit and an active bypass circuit that is activated after the inrush current peak decays. This paper presents an investigation of a simple method to manage the inrush current during the compressor starting up each start-stop cycle. This procedure includes switch OFF the unit's fan just before the compressor starting up to provide an extra power to minimising the unit total inrush current. While the fan is continue rotating by its inertia and when the compressor reaches its steady state current or just before it, the fan is reconnected. Inrush current of the fan in this case will significantly reduce because it is continue rotating. High inrush current is needed to start any electrical motor from its idle to rotating state at its steady state speed.\",\"PeriodicalId\":404735,\"journal\":{\"name\":\"2018 11th International Conference on Developments in eSystems Engineering (DeSE)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 11th International Conference on Developments in eSystems Engineering (DeSE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DeSE.2018.00020\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 11th International Conference on Developments in eSystems Engineering (DeSE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DeSE.2018.00020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在炎热的夏季,家用空调设备每天长时间运行,以创造舒适的环境。相反,使用这些单位可能会涉及很多风险。空调机组是高耗电量的电器之一。每次制冷剂压缩机启动时,这种功率会产生浪涌,导致电气连接温度升高。再加上极端炎热的天气,居民的生命和财产处于真正的危险之中。由于每次压缩机启动时产生的涌流电流通过连接处,导致连接处出现众所周知的加热-冷却循环,从而导致连接处变弱。随着时间的推移,这些连接变得越来越热,达到特定的温度,可能会引发火灾,并且/或有毒气体可能会从插座和接头中释放出来。制造商开始在电源电路中使用浪涌电流限制器和在浪涌电流峰值衰减后激活的有源旁路电路。本文研究了一种控制压缩机启动过程中各启停周期涌流的简单方法。该程序包括在压缩机启动之前关闭机组的风扇,以提供额外的功率,以最小化机组的总涌流电流。当风扇继续转动时,当压缩机达到稳态电流或即将达到稳态电流时,风扇重新连接。在这种情况下,风机的涌流将大大减少,因为它是持续旋转。要使电动机以稳态速度从空转到旋转状态,都需要较大的涌流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power Management of Domestic Air Condition Units
Domestic air conditioner equipment run long time a day to create a comfortable environment during hot summer weather. Instead of this, using such units may involve lots of risks. Air condition unit is one of the high electric power consumption appliances. This power surges each time the refrigerant compressor starts up leads to increase the temperature of electric connections. Coupled with the extreme hot weather put the resident's lives and their properties in real danger. A well-known heating-cooling cycle of the electric connections due to increasing-decreasing electric current cycle passing through the connections as a result of inrush current each time the compressor starting up leads to weak them. With the time, these connections become hotter and hotter to a specific temperature at which fire may ignite and/ or poisoning gases may emit from sockets and joints. Manufacturers start using inrush current limiters in the power circuit and an active bypass circuit that is activated after the inrush current peak decays. This paper presents an investigation of a simple method to manage the inrush current during the compressor starting up each start-stop cycle. This procedure includes switch OFF the unit's fan just before the compressor starting up to provide an extra power to minimising the unit total inrush current. While the fan is continue rotating by its inertia and when the compressor reaches its steady state current or just before it, the fan is reconnected. Inrush current of the fan in this case will significantly reduce because it is continue rotating. High inrush current is needed to start any electrical motor from its idle to rotating state at its steady state speed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信