使用多速率FIR滤波器的时间序列心率计算

M. Risk, D. Ślȩzak, P. Turjanski, A. Panelli, R. Taborda, G. Marshall
{"title":"使用多速率FIR滤波器的时间序列心率计算","authors":"M. Risk, D. Ślȩzak, P. Turjanski, A. Panelli, R. Taborda, G. Marshall","doi":"10.1109/CIC.2007.4745542","DOIUrl":null,"url":null,"abstract":"The spectral analysis of heart rate variability, based on the Fourier transform, needs even sampled data. The objectives of this study were to develop an interpolation method based on multi rate FIR filters, and then to implement this method for parallel processing machines. A total of three data sets were used: a) simulated heart rate with an IPFM model, b) autonomic blockage database (both pharmacological and postural), and c) long term Holter studies (recordings of 24 hours). Spectral analysis, for the three data sets, was processed for both interpolation using FIR filters and cubic splines, the results for Bland and Altman analysis for low frequency band, showed a difference of -47plusmn131 ms2; then for the high frequency band, the difference was 3plusmn48 ms2. The presented method of time series calculation, using FIR filters, probed to be equivalent for both simulated and real data, and is suitable for parallel programming implementation.","PeriodicalId":406683,"journal":{"name":"2007 Computers in Cardiology","volume":"91 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Time series calculation of heart rate using multi rate FIR filters\",\"authors\":\"M. Risk, D. Ślȩzak, P. Turjanski, A. Panelli, R. Taborda, G. Marshall\",\"doi\":\"10.1109/CIC.2007.4745542\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The spectral analysis of heart rate variability, based on the Fourier transform, needs even sampled data. The objectives of this study were to develop an interpolation method based on multi rate FIR filters, and then to implement this method for parallel processing machines. A total of three data sets were used: a) simulated heart rate with an IPFM model, b) autonomic blockage database (both pharmacological and postural), and c) long term Holter studies (recordings of 24 hours). Spectral analysis, for the three data sets, was processed for both interpolation using FIR filters and cubic splines, the results for Bland and Altman analysis for low frequency band, showed a difference of -47plusmn131 ms2; then for the high frequency band, the difference was 3plusmn48 ms2. The presented method of time series calculation, using FIR filters, probed to be equivalent for both simulated and real data, and is suitable for parallel programming implementation.\",\"PeriodicalId\":406683,\"journal\":{\"name\":\"2007 Computers in Cardiology\",\"volume\":\"91 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 Computers in Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2007.4745542\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Computers in Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2007.4745542","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

基于傅里叶变换的心率变异性频谱分析需要均匀采样数据。本研究的目的是建立一种基于多速率FIR滤波器的插值方法,并将该方法应用于并行加工机床。总共使用了三个数据集:A) IPFM模型模拟心率,b)自主神经阻塞数据库(药理学和体位学),c)长期霍尔特研究(24小时记录)。对三个数据集进行了光谱分析,分别使用FIR滤波器和三次样条进行插值处理,对低频波段进行Bland和Altman分析的结果显示差异为-47plusmn131 ms2;对于高频波段,差异为3plusmn48 ms2。本文提出的时间序列计算方法采用FIR滤波器,对模拟数据和实际数据具有等效性,适合于并行编程实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Time series calculation of heart rate using multi rate FIR filters
The spectral analysis of heart rate variability, based on the Fourier transform, needs even sampled data. The objectives of this study were to develop an interpolation method based on multi rate FIR filters, and then to implement this method for parallel processing machines. A total of three data sets were used: a) simulated heart rate with an IPFM model, b) autonomic blockage database (both pharmacological and postural), and c) long term Holter studies (recordings of 24 hours). Spectral analysis, for the three data sets, was processed for both interpolation using FIR filters and cubic splines, the results for Bland and Altman analysis for low frequency band, showed a difference of -47plusmn131 ms2; then for the high frequency band, the difference was 3plusmn48 ms2. The presented method of time series calculation, using FIR filters, probed to be equivalent for both simulated and real data, and is suitable for parallel programming implementation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信