线路电流调制高频链路直流到公用事业接口电源变换器的输入输出谐波

A. Bhat, S. Dewan
{"title":"线路电流调制高频链路直流到公用事业接口电源变换器的输入输出谐波","authors":"A. Bhat, S. Dewan","doi":"10.1109/APEC.1986.7073313","DOIUrl":null,"url":null,"abstract":"Two types of commutation schemes (called Type I and Type II ) are proposed and analyzed for the line connected inverter (LCI) used in line current modulated high frequency (hf) link DC to utility interface power conditioning (DC/UIPC) systems. In Type I scheme [2,4], the hf inverter is switched off well in advance of the zero crossings of line voltage, allowing the line current to go to zero and enabling the LCI to turn off. A simple lossless forced commutation circuit is used in Type II [2] scheme. The effects of these schemes on line side and input dc side current harmonics are studied in the case of l-ϕ systems, neglecting the effect of controller action. The performance indices are evaluated. The results obtained from prototype experimental systems are used to verify the theory presented. The analysis presented for 1-0 systems is extended to 3-0 systems.","PeriodicalId":302790,"journal":{"name":"1986 IEEE Applied Power Electronics Conference and Exposition","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1986-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Input-output harmonics of line current modulated high-frequency link DC to utility interface power converters\",\"authors\":\"A. Bhat, S. Dewan\",\"doi\":\"10.1109/APEC.1986.7073313\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two types of commutation schemes (called Type I and Type II ) are proposed and analyzed for the line connected inverter (LCI) used in line current modulated high frequency (hf) link DC to utility interface power conditioning (DC/UIPC) systems. In Type I scheme [2,4], the hf inverter is switched off well in advance of the zero crossings of line voltage, allowing the line current to go to zero and enabling the LCI to turn off. A simple lossless forced commutation circuit is used in Type II [2] scheme. The effects of these schemes on line side and input dc side current harmonics are studied in the case of l-ϕ systems, neglecting the effect of controller action. The performance indices are evaluated. The results obtained from prototype experimental systems are used to verify the theory presented. The analysis presented for 1-0 systems is extended to 3-0 systems.\",\"PeriodicalId\":302790,\"journal\":{\"name\":\"1986 IEEE Applied Power Electronics Conference and Exposition\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1986 IEEE Applied Power Electronics Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.1986.7073313\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1986 IEEE Applied Power Electronics Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.1986.7073313","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

针对线电流调制高频(hf)链路直流到公用接口功率调节(DC/UIPC)系统中使用的线路连接逆变器(LCI),提出并分析了两种类型的换相方案(I型和II型)。在I型方案[2,4]中,高频逆变器在线路电压过零时提前断开,使线路电流归零,使LCI断开。II型[2]方案采用简单的无损强制换相电路。在l- φ系统的情况下,研究了这些方案对线侧和输入直流侧电流谐波的影响,忽略了控制器作用的影响。对各性能指标进行了评价。从原型实验系统得到的结果用于验证所提出的理论。将1-0系统的分析推广到3-0系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Input-output harmonics of line current modulated high-frequency link DC to utility interface power converters
Two types of commutation schemes (called Type I and Type II ) are proposed and analyzed for the line connected inverter (LCI) used in line current modulated high frequency (hf) link DC to utility interface power conditioning (DC/UIPC) systems. In Type I scheme [2,4], the hf inverter is switched off well in advance of the zero crossings of line voltage, allowing the line current to go to zero and enabling the LCI to turn off. A simple lossless forced commutation circuit is used in Type II [2] scheme. The effects of these schemes on line side and input dc side current harmonics are studied in the case of l-ϕ systems, neglecting the effect of controller action. The performance indices are evaluated. The results obtained from prototype experimental systems are used to verify the theory presented. The analysis presented for 1-0 systems is extended to 3-0 systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信