Joong-Ho Song, Sungjoon Cho, I. Choy, Ju-Yeop Choi
{"title":"单相三电平PWM整流器的新PWM方法","authors":"Joong-Ho Song, Sungjoon Cho, I. Choy, Ju-Yeop Choi","doi":"10.1109/ISIE.1997.648951","DOIUrl":null,"url":null,"abstract":"This paper presents a simple switching method to generate a PWM pattern mostly relevant to single-phase three-level PWM rectifiers. The adopted PWM switching pattern is performed in a manner similar to the space vector PWM method, which is popularly used in three-phase rectifiers and inverters. A set of possible voltages is selected so that an equation with a time integral considered within a sampling period should be satisfied every sampling time. The simulation results show that the proposed control scheme produces good characteristics comparable to a conventional method of using a set of triangular carriers in some performance criteria such as unity power factor, low harmonic distortion of input current and voltage balancing of two series-connected DC capacitors.","PeriodicalId":134474,"journal":{"name":"ISIE '97 Proceeding of the IEEE International Symposium on Industrial Electronics","volume":"103 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"New PWM method for single-phase three-level PWM rectifiers\",\"authors\":\"Joong-Ho Song, Sungjoon Cho, I. Choy, Ju-Yeop Choi\",\"doi\":\"10.1109/ISIE.1997.648951\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a simple switching method to generate a PWM pattern mostly relevant to single-phase three-level PWM rectifiers. The adopted PWM switching pattern is performed in a manner similar to the space vector PWM method, which is popularly used in three-phase rectifiers and inverters. A set of possible voltages is selected so that an equation with a time integral considered within a sampling period should be satisfied every sampling time. The simulation results show that the proposed control scheme produces good characteristics comparable to a conventional method of using a set of triangular carriers in some performance criteria such as unity power factor, low harmonic distortion of input current and voltage balancing of two series-connected DC capacitors.\",\"PeriodicalId\":134474,\"journal\":{\"name\":\"ISIE '97 Proceeding of the IEEE International Symposium on Industrial Electronics\",\"volume\":\"103 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-07-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISIE '97 Proceeding of the IEEE International Symposium on Industrial Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.1997.648951\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISIE '97 Proceeding of the IEEE International Symposium on Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.1997.648951","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
New PWM method for single-phase three-level PWM rectifiers
This paper presents a simple switching method to generate a PWM pattern mostly relevant to single-phase three-level PWM rectifiers. The adopted PWM switching pattern is performed in a manner similar to the space vector PWM method, which is popularly used in three-phase rectifiers and inverters. A set of possible voltages is selected so that an equation with a time integral considered within a sampling period should be satisfied every sampling time. The simulation results show that the proposed control scheme produces good characteristics comparable to a conventional method of using a set of triangular carriers in some performance criteria such as unity power factor, low harmonic distortion of input current and voltage balancing of two series-connected DC capacitors.