{"title":"一种快速实用的相位测量轮廓校正方法","authors":"Lei Wu, Yanshan Xiao, Zi-wei Liu, Longfei Han","doi":"10.1117/12.2181806","DOIUrl":null,"url":null,"abstract":"In the traditional PMP calibration, the system calibration and phase measurement were performed dividedly, and the measurement result was the relative height to the reference plane. A fast calibration was proposed, in which two gauge blocks were used to replace the standard plane controlled by the mechanical shifting device in the traditional calibration, and fewer datum points were sampled from the surface of the gauge blocks to calibrate the system. With this method, both system calibration and phase measurement can be implemented simultaneously. The real height of the object relative to the supporting plane can be obtained when the supporting plane was not superposed on the reference. A cuboid block of normal height 14.00mm was successfully measured by this method. Its mean relative error was no more than 1.35% and the root-mean-square error was less than 0.15mm. The calibration of the PMP was simplified and became more flexible with the proposed method.","PeriodicalId":225534,"journal":{"name":"Photoelectronic Technology Committee Conferences","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A fast and practical calibration method for the phase measuring profilometry\",\"authors\":\"Lei Wu, Yanshan Xiao, Zi-wei Liu, Longfei Han\",\"doi\":\"10.1117/12.2181806\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the traditional PMP calibration, the system calibration and phase measurement were performed dividedly, and the measurement result was the relative height to the reference plane. A fast calibration was proposed, in which two gauge blocks were used to replace the standard plane controlled by the mechanical shifting device in the traditional calibration, and fewer datum points were sampled from the surface of the gauge blocks to calibrate the system. With this method, both system calibration and phase measurement can be implemented simultaneously. The real height of the object relative to the supporting plane can be obtained when the supporting plane was not superposed on the reference. A cuboid block of normal height 14.00mm was successfully measured by this method. Its mean relative error was no more than 1.35% and the root-mean-square error was less than 0.15mm. The calibration of the PMP was simplified and became more flexible with the proposed method.\",\"PeriodicalId\":225534,\"journal\":{\"name\":\"Photoelectronic Technology Committee Conferences\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Photoelectronic Technology Committee Conferences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2181806\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photoelectronic Technology Committee Conferences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2181806","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A fast and practical calibration method for the phase measuring profilometry
In the traditional PMP calibration, the system calibration and phase measurement were performed dividedly, and the measurement result was the relative height to the reference plane. A fast calibration was proposed, in which two gauge blocks were used to replace the standard plane controlled by the mechanical shifting device in the traditional calibration, and fewer datum points were sampled from the surface of the gauge blocks to calibrate the system. With this method, both system calibration and phase measurement can be implemented simultaneously. The real height of the object relative to the supporting plane can be obtained when the supporting plane was not superposed on the reference. A cuboid block of normal height 14.00mm was successfully measured by this method. Its mean relative error was no more than 1.35% and the root-mean-square error was less than 0.15mm. The calibration of the PMP was simplified and became more flexible with the proposed method.