DFIG风电配电网故障分析

Yang Beige, Xue Hui, Bai Dan-dan, Hu Wei, He Jinghan
{"title":"DFIG风电配电网故障分析","authors":"Yang Beige, Xue Hui, Bai Dan-dan, Hu Wei, He Jinghan","doi":"10.1109/ISGTEUROPE.2011.6162716","DOIUrl":null,"url":null,"abstract":"With high penetrations of wind energy, different types of wind farm generators do not have the same fault transient characteristics that can complicate the selection and configuration of wind farm grid protection equipment. Incorrect selection of protection equipment will affect the stability and of the power systems. This paper investigates and analyzes the transient characteristics of doubly-fed induction generator (DFIG) under various short-circuit fault conditions for a typical distribution network. Firstly a detailed model of the DFIG and its principles is descried. A realistic of a 99 MW wind farm with 66 units of 1.5 MW DFIG is modeled using RTDS/RSCAD. The transient characteristic of the wind farm with the DFIG units have been analyzed under different short-circuit fault conditions. Results from the fault performance study on the distribution network are presented and discussed.","PeriodicalId":419250,"journal":{"name":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fault analysis of distribution network with wind turbines of DFIG\",\"authors\":\"Yang Beige, Xue Hui, Bai Dan-dan, Hu Wei, He Jinghan\",\"doi\":\"10.1109/ISGTEUROPE.2011.6162716\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With high penetrations of wind energy, different types of wind farm generators do not have the same fault transient characteristics that can complicate the selection and configuration of wind farm grid protection equipment. Incorrect selection of protection equipment will affect the stability and of the power systems. This paper investigates and analyzes the transient characteristics of doubly-fed induction generator (DFIG) under various short-circuit fault conditions for a typical distribution network. Firstly a detailed model of the DFIG and its principles is descried. A realistic of a 99 MW wind farm with 66 units of 1.5 MW DFIG is modeled using RTDS/RSCAD. The transient characteristic of the wind farm with the DFIG units have been analyzed under different short-circuit fault conditions. Results from the fault performance study on the distribution network are presented and discussed.\",\"PeriodicalId\":419250,\"journal\":{\"name\":\"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies\",\"volume\":\"96 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEUROPE.2011.6162716\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEUROPE.2011.6162716","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于风能穿透度高,不同类型的风电场发电机故障暂态特征不相同,这给风电场电网保护设备的选择和配置带来了复杂性。保护设备的选择不当将影响电力系统的稳定运行。研究和分析了典型配电网在各种短路故障条件下双馈感应发电机的暂态特性。首先介绍了DFIG的详细模型及其原理。使用RTDS/RSCAD对一个99兆瓦风电场的66个1.5兆瓦DFIG机组进行了建模。分析了不同短路故障条件下安装DFIG机组的风电场的暂态特性。介绍并讨论了配电网故障性能研究的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fault analysis of distribution network with wind turbines of DFIG
With high penetrations of wind energy, different types of wind farm generators do not have the same fault transient characteristics that can complicate the selection and configuration of wind farm grid protection equipment. Incorrect selection of protection equipment will affect the stability and of the power systems. This paper investigates and analyzes the transient characteristics of doubly-fed induction generator (DFIG) under various short-circuit fault conditions for a typical distribution network. Firstly a detailed model of the DFIG and its principles is descried. A realistic of a 99 MW wind farm with 66 units of 1.5 MW DFIG is modeled using RTDS/RSCAD. The transient characteristic of the wind farm with the DFIG units have been analyzed under different short-circuit fault conditions. Results from the fault performance study on the distribution network are presented and discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信