Jun-Chau Chien, M. Anwar, E. Yeh, Luke P. Lee, A. Niknejad
{"title":"1-50 GHz介电光谱生物传感器,集成接收器前端为65nm CMOS","authors":"Jun-Chau Chien, M. Anwar, E. Yeh, Luke P. Lee, A. Niknejad","doi":"10.1109/MWSYM.2013.6697466","DOIUrl":null,"url":null,"abstract":"In this paper, an on-chip transmission-line sensor with integrated receiver front-end implemented in 65nm CMOS facilitates the measurement of complex permittivity from 1 to 50 GHz for liquid samples. A robust extraction model allows accurate prediction of sample permittivity based on reference liquid calibration and eases the design of the hardware. Front-end circuits include a 60 GHz distributed amplifier with noise-cancellation active termination to improve the noise figure below 18 GHz. Correlated-double-sampling technique is used in the measurement setup to reject system phase drift. The sensor achieves 1% permittivity sensitivity at 20 GHz through liquid measurements with a minimum sensing volume of 0.09 nL. The prototype chip consumes a total power of 114 mW.","PeriodicalId":128968,"journal":{"name":"2013 IEEE MTT-S International Microwave Symposium Digest (MTT)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"40","resultStr":"{\"title\":\"A 1–50 GHz dielectric spectroscopy biosensor with integrated receiver front-end in 65nm CMOS\",\"authors\":\"Jun-Chau Chien, M. Anwar, E. Yeh, Luke P. Lee, A. Niknejad\",\"doi\":\"10.1109/MWSYM.2013.6697466\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, an on-chip transmission-line sensor with integrated receiver front-end implemented in 65nm CMOS facilitates the measurement of complex permittivity from 1 to 50 GHz for liquid samples. A robust extraction model allows accurate prediction of sample permittivity based on reference liquid calibration and eases the design of the hardware. Front-end circuits include a 60 GHz distributed amplifier with noise-cancellation active termination to improve the noise figure below 18 GHz. Correlated-double-sampling technique is used in the measurement setup to reject system phase drift. The sensor achieves 1% permittivity sensitivity at 20 GHz through liquid measurements with a minimum sensing volume of 0.09 nL. The prototype chip consumes a total power of 114 mW.\",\"PeriodicalId\":128968,\"journal\":{\"name\":\"2013 IEEE MTT-S International Microwave Symposium Digest (MTT)\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"40\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE MTT-S International Microwave Symposium Digest (MTT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MWSYM.2013.6697466\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE MTT-S International Microwave Symposium Digest (MTT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.2013.6697466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A 1–50 GHz dielectric spectroscopy biosensor with integrated receiver front-end in 65nm CMOS
In this paper, an on-chip transmission-line sensor with integrated receiver front-end implemented in 65nm CMOS facilitates the measurement of complex permittivity from 1 to 50 GHz for liquid samples. A robust extraction model allows accurate prediction of sample permittivity based on reference liquid calibration and eases the design of the hardware. Front-end circuits include a 60 GHz distributed amplifier with noise-cancellation active termination to improve the noise figure below 18 GHz. Correlated-double-sampling technique is used in the measurement setup to reject system phase drift. The sensor achieves 1% permittivity sensitivity at 20 GHz through liquid measurements with a minimum sensing volume of 0.09 nL. The prototype chip consumes a total power of 114 mW.