I. Yamato, N. Tokunaga, Y. Matsuda, H. Amano, Y. Suzuki
{"title":"采用高频链路的新型UPS转换系统","authors":"I. Yamato, N. Tokunaga, Y. Matsuda, H. Amano, Y. Suzuki","doi":"10.1109/PESC.1988.18193","DOIUrl":null,"url":null,"abstract":"A novel conversion system for a UPS (uninterruptible power supply) using a high-frequency link is described. The UPS consists of a high-frequency inverter and transformer and a cycloconverter. The cycloconverter can be operated by both source commutation and self-commutation (by turning off the switching devices). A choice is made between the two commutation methods, depending on switching device losses during commutation and the internal voltage drop caused by commutating reactance. A compact and efficient UPS can be realized with this conversion system.<<ETX>>","PeriodicalId":283605,"journal":{"name":"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"71","resultStr":"{\"title\":\"New conversion system for UPS using high frequency link\",\"authors\":\"I. Yamato, N. Tokunaga, Y. Matsuda, H. Amano, Y. Suzuki\",\"doi\":\"10.1109/PESC.1988.18193\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel conversion system for a UPS (uninterruptible power supply) using a high-frequency link is described. The UPS consists of a high-frequency inverter and transformer and a cycloconverter. The cycloconverter can be operated by both source commutation and self-commutation (by turning off the switching devices). A choice is made between the two commutation methods, depending on switching device losses during commutation and the internal voltage drop caused by commutating reactance. A compact and efficient UPS can be realized with this conversion system.<<ETX>>\",\"PeriodicalId\":283605,\"journal\":{\"name\":\"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference\",\"volume\":\"24 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1988-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"71\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESC.1988.18193\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1988.18193","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
New conversion system for UPS using high frequency link
A novel conversion system for a UPS (uninterruptible power supply) using a high-frequency link is described. The UPS consists of a high-frequency inverter and transformer and a cycloconverter. The cycloconverter can be operated by both source commutation and self-commutation (by turning off the switching devices). A choice is made between the two commutation methods, depending on switching device losses during commutation and the internal voltage drop caused by commutating reactance. A compact and efficient UPS can be realized with this conversion system.<>