Yin-Cheng Chang, Shuw-Guann Lin, Hsien-Yuan Liao, H. Chiou, Y. Juang
{"title":"低噪声放大器的片上差分噪声图和大信号测量","authors":"Yin-Cheng Chang, Shuw-Guann Lin, Hsien-Yuan Liao, H. Chiou, Y. Juang","doi":"10.23919/eumc.2009.5296568","DOIUrl":null,"url":null,"abstract":"An on-wafer measurement technique is proposed to characterize the differential noise figure (NF), 1-dB compression point (P1dB) and input third order intercept point (IP3) of low-noise amplifier (LNA). This work successfully extends Friis equation to the generalized two-port case by introducing true differential mode concept. The correlated differential NF is accurately obtained after de-embedding the noise contribution from the interconnections and external components. Details of equations and measurement procedure are reported in this work. A 2.6 GHz differential LNA was tested to demonstrate the feasibility of measurement and showed precise NF compared with other methods. A large signal measurement based on true differential mode stimulus with the same test bench was also performed and presented accurate results.","PeriodicalId":232128,"journal":{"name":"2009 European Microwave Conference (EuMC)","volume":"117 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"On-wafer differential noise figure and large signal measurements of low-noise amplifier\",\"authors\":\"Yin-Cheng Chang, Shuw-Guann Lin, Hsien-Yuan Liao, H. Chiou, Y. Juang\",\"doi\":\"10.23919/eumc.2009.5296568\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An on-wafer measurement technique is proposed to characterize the differential noise figure (NF), 1-dB compression point (P1dB) and input third order intercept point (IP3) of low-noise amplifier (LNA). This work successfully extends Friis equation to the generalized two-port case by introducing true differential mode concept. The correlated differential NF is accurately obtained after de-embedding the noise contribution from the interconnections and external components. Details of equations and measurement procedure are reported in this work. A 2.6 GHz differential LNA was tested to demonstrate the feasibility of measurement and showed precise NF compared with other methods. A large signal measurement based on true differential mode stimulus with the same test bench was also performed and presented accurate results.\",\"PeriodicalId\":232128,\"journal\":{\"name\":\"2009 European Microwave Conference (EuMC)\",\"volume\":\"117 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 European Microwave Conference (EuMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/eumc.2009.5296568\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 European Microwave Conference (EuMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/eumc.2009.5296568","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On-wafer differential noise figure and large signal measurements of low-noise amplifier
An on-wafer measurement technique is proposed to characterize the differential noise figure (NF), 1-dB compression point (P1dB) and input third order intercept point (IP3) of low-noise amplifier (LNA). This work successfully extends Friis equation to the generalized two-port case by introducing true differential mode concept. The correlated differential NF is accurately obtained after de-embedding the noise contribution from the interconnections and external components. Details of equations and measurement procedure are reported in this work. A 2.6 GHz differential LNA was tested to demonstrate the feasibility of measurement and showed precise NF compared with other methods. A large signal measurement based on true differential mode stimulus with the same test bench was also performed and presented accurate results.