H. Shao, Feipeng Lin, B. Liang, Huanghui Zhang, Wei Zhao, Jiafu Wang, Chuansheng Li
{"title":"110kv LVE-TSVT电压依赖性测量","authors":"H. Shao, Feipeng Lin, B. Liang, Huanghui Zhang, Wei Zhao, Jiafu Wang, Chuansheng Li","doi":"10.1109/CPEM.2016.7540802","DOIUrl":null,"url":null,"abstract":"The paper presents the development of a 35 kV fully-insulated two-stage voltage transformer(TSVT), and its applications by connecting in series with another 35 kV semi-insulated TSVT to determine the voltage dependence(VD) of a 110 kV TSVT. The result showed the VD of the 110 kV TSVT is around -1.6×10-6 and +1.6 μrad in magnitude and phase, respectively.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Voltage dependence measurement of a 110 kV LVE-TSVT\",\"authors\":\"H. Shao, Feipeng Lin, B. Liang, Huanghui Zhang, Wei Zhao, Jiafu Wang, Chuansheng Li\",\"doi\":\"10.1109/CPEM.2016.7540802\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents the development of a 35 kV fully-insulated two-stage voltage transformer(TSVT), and its applications by connecting in series with another 35 kV semi-insulated TSVT to determine the voltage dependence(VD) of a 110 kV TSVT. The result showed the VD of the 110 kV TSVT is around -1.6×10-6 and +1.6 μrad in magnitude and phase, respectively.\",\"PeriodicalId\":415488,\"journal\":{\"name\":\"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2016.7540802\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2016.7540802","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Voltage dependence measurement of a 110 kV LVE-TSVT
The paper presents the development of a 35 kV fully-insulated two-stage voltage transformer(TSVT), and its applications by connecting in series with another 35 kV semi-insulated TSVT to determine the voltage dependence(VD) of a 110 kV TSVT. The result showed the VD of the 110 kV TSVT is around -1.6×10-6 and +1.6 μrad in magnitude and phase, respectively.