单相有源电力线调节器的一种新的控制方法

Yu-Kang Lo, Lian-Chen Kuo
{"title":"单相有源电力线调节器的一种新的控制方法","authors":"Yu-Kang Lo, Lian-Chen Kuo","doi":"10.1109/APEC.1999.750513","DOIUrl":null,"url":null,"abstract":"A new control method for single-phase shunt active power line conditioners (APLCs) operated under zero average power consumption is proposed in this paper. The amplitude of the sinusoidal source current which is in-phase with the source voltage can be determined from the average value of the instantaneous load power. Then the command current for the shunt APLC is obtained by subtracting the source current from the load current. Neither bulky filter nor time-consuming computation is required. The shunt power compensator supplies all the harmonics of the load current and the source only supplies the fundamental component. Experimental results on a prototype verify the feasibility of the presented scheme.","PeriodicalId":287192,"journal":{"name":"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"A new control method for single-phase active power line conditioners\",\"authors\":\"Yu-Kang Lo, Lian-Chen Kuo\",\"doi\":\"10.1109/APEC.1999.750513\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new control method for single-phase shunt active power line conditioners (APLCs) operated under zero average power consumption is proposed in this paper. The amplitude of the sinusoidal source current which is in-phase with the source voltage can be determined from the average value of the instantaneous load power. Then the command current for the shunt APLC is obtained by subtracting the source current from the load current. Neither bulky filter nor time-consuming computation is required. The shunt power compensator supplies all the harmonics of the load current and the source only supplies the fundamental component. Experimental results on a prototype verify the feasibility of the presented scheme.\",\"PeriodicalId\":287192,\"journal\":{\"name\":\"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-03-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.1999.750513\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.1999.750513","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

提出了一种新的单相并联有源电力线调节器(aplc)在零平均功耗下运行的控制方法。正弦源电流与源电压同相的幅值可由瞬时负载功率的平均值确定。然后,通过从负载电流中减去源电流获得分流APLC的命令电流。既不需要庞大的过滤器,也不需要耗时的计算。并联电源补偿器提供负载电流的所有谐波,电源只提供基波分量。在样机上的实验结果验证了该方案的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new control method for single-phase active power line conditioners
A new control method for single-phase shunt active power line conditioners (APLCs) operated under zero average power consumption is proposed in this paper. The amplitude of the sinusoidal source current which is in-phase with the source voltage can be determined from the average value of the instantaneous load power. Then the command current for the shunt APLC is obtained by subtracting the source current from the load current. Neither bulky filter nor time-consuming computation is required. The shunt power compensator supplies all the harmonics of the load current and the source only supplies the fundamental component. Experimental results on a prototype verify the feasibility of the presented scheme.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信