感应发电机的静态分岔

O. Ojo
{"title":"感应发电机的静态分岔","authors":"O. Ojo","doi":"10.1109/SSST.1990.138156","DOIUrl":null,"url":null,"abstract":"Summary form only given. A simplified approach to studying the phenomenon of self-excitation in induction generators, based on the concept of static bifurcation and the q-d equivalent circuit equation in the synchronous reference frame, is proposed. This approach provides the necessary framework for identifying the boundary of possible self-excitation for a generalized load comprising both resistive and inductive loads. Example of these boundaries are shown. The limitation of capacitive self-excited induction generator operation has been determined, and suggestions as to how constant voltage and frequency power can be attained have been derived on the basis of the bifurcation fields. For the cases in which the reactive power is provided from a pulsewidth-modulated inverter, it has been shown how the switching frequency and the effective value of the inverter capacitance can be appropriately and structurally manipulated to obtain constant voltage and constant frequency power from the generator.<<ETX>>","PeriodicalId":201543,"journal":{"name":"[1990] Proceedings. The Twenty-Second Southeastern Symposium on System Theory","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Static bifurcation in induction generators\",\"authors\":\"O. Ojo\",\"doi\":\"10.1109/SSST.1990.138156\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Summary form only given. A simplified approach to studying the phenomenon of self-excitation in induction generators, based on the concept of static bifurcation and the q-d equivalent circuit equation in the synchronous reference frame, is proposed. This approach provides the necessary framework for identifying the boundary of possible self-excitation for a generalized load comprising both resistive and inductive loads. Example of these boundaries are shown. The limitation of capacitive self-excited induction generator operation has been determined, and suggestions as to how constant voltage and frequency power can be attained have been derived on the basis of the bifurcation fields. For the cases in which the reactive power is provided from a pulsewidth-modulated inverter, it has been shown how the switching frequency and the effective value of the inverter capacitance can be appropriately and structurally manipulated to obtain constant voltage and constant frequency power from the generator.<<ETX>>\",\"PeriodicalId\":201543,\"journal\":{\"name\":\"[1990] Proceedings. The Twenty-Second Southeastern Symposium on System Theory\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1990] Proceedings. The Twenty-Second Southeastern Symposium on System Theory\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SSST.1990.138156\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1990] Proceedings. The Twenty-Second Southeastern Symposium on System Theory","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SSST.1990.138156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

只提供摘要形式。基于静态分岔的概念和同步参照系下的q-d等效电路方程,提出了一种研究感应发电机自激现象的简化方法。这种方法为确定由电阻性和感性负载组成的广义负载的可能自激边界提供了必要的框架。下面是这些边界的例子。确定了电容式自激感应发电机运行的局限性,并在分岔场的基础上提出了如何获得恒压恒频功率的建议。对于由脉宽调制逆变器提供无功功率的情况,本文展示了如何在结构上适当地操纵开关频率和逆变器电容的有效值,以从发电机获得恒压恒频的功率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Static bifurcation in induction generators
Summary form only given. A simplified approach to studying the phenomenon of self-excitation in induction generators, based on the concept of static bifurcation and the q-d equivalent circuit equation in the synchronous reference frame, is proposed. This approach provides the necessary framework for identifying the boundary of possible self-excitation for a generalized load comprising both resistive and inductive loads. Example of these boundaries are shown. The limitation of capacitive self-excited induction generator operation has been determined, and suggestions as to how constant voltage and frequency power can be attained have been derived on the basis of the bifurcation fields. For the cases in which the reactive power is provided from a pulsewidth-modulated inverter, it has been shown how the switching frequency and the effective value of the inverter capacitance can be appropriately and structurally manipulated to obtain constant voltage and constant frequency power from the generator.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信